Fixed Tubesheet Heat Exchanger in Abaqus: Plastic Load and Limit Load Replication of a Journal Paper

€99,00
Optional extras

Need a full custom project? See the options below.

€99,00
Optional extras

Need a full custom project? See the options below.

23 people watching this product now!

Material Includes

  • PDF tutorial
  • Abaqus/CAE 2024 file with 7 models
  • Input decks of all cases and the shared mesh
  • Key result images and a short README

Audience

  • Pressure vessel and heat exchanger engineers using ASME VIII-2 design by analysis
  • FEA engineers who need a benchmark for limit and plastic load evaluation
  • Researchers and students of plastic collapse criteria

What You Will Learn?

  • Build and run a 3-D sector model of a fixed tubesheet heat exchanger with every tube hole in Abaqus.
  • Run an elastic-perfectly plastic limit analysis and elastic-plastic analyses with bilinear and ASME multilinear material.
  • Compare isotropic, kinematic and combined hardening, and small against large deformation.
  • Evaluate twice elastic slope, tangent intersection, plastic work curvature and strain-limit plastic loads from the Abaqus history output.
  • See why different plastic-load criteria disagree, with a diagnostic run that isolates the cause.

About Course

Fixed tubesheet heat exchangers are designed against plastic collapse, and the design-by-analysis route of ASME Section VIII Division 2 asks for a plastic load from an elastic-plastic finite element analysis. Which criterion you use to read that load from the analysis (limit load, twice elastic slope, tangent intersection, plastic work curvature or a strain limit) can change the answer by tens of percent. This Abaqus package rebuilds the fixed tubesheet heat exchanger of a published paper, runs the elastic-perfectly plastic limit analysis and six elastic-plastic cases, and evaluates every criterion the paper reports, so you can see where they agree and where they do not.

Honest status: partial validation. The limit load is 11.41 MPa against the paper’s 11.7 MPa (-2.4%) with the same collapse mechanism. The plastic work curvature load agrees within -1.3% to -3.7% and the load at 5% plastic strain within -6.0% to -8.7% in three of the four small-deformation cases. The twice-elastic-slope load is about 30% lower than the paper in every case, and the multilinear large-deformation instability load is 16.2 MPa against 21 MPa. Both gaps are shown in every table and figure, nothing was tuned to close them, and the tutorial explains them with a diagnostic run.

Fixed tubesheet heat exchanger in Abaqus: plastic strain at the shell junction and the EPP limit load within 2.4% of the paper
Fixed tubesheet heat exchanger in Abaqus: plastic strain at the shell junction and the EPP limit load within 2.4% of the paper

Watch the short

The paper behind the model

K. Behseta, D. Mackenzie, R. Hamilton, "Plastic load evaluation for a fixed tube sheet heat exchanger subject to proportional loading", International Journal of Pressure Vessels and Piping 92 (2012) 11-18.

What the paper does. It analyses a fixed tubesheet heat exchanger under tube-side pressure with a 3-D finite element model and compares plastic-load criteria for elastic-perfectly plastic, bilinear and multilinear (ASME VIII-2 Annex 3-D) material, with isotropic and kinematic hardening, in small and large deformation.

What this package reproduces. The geometry of the paper’s Fig. 4, the limit analysis, the four small-deformation hardening cases of Tables 2 and 3 and the two large-deformation cases of Table 4, with the same criteria. The paper does not give the tube pitch and count, the shell length or the channel head, so these are assumptions listed below. The paper is cited but not included, and none of its figures are used on this page; only its published values are compared.

Fixed tubesheet model at a glance

Tubesheet100 mm thick, SA266, 12.5 mm grooves on both faces at the shell junction
TubesØ57 × 2.9 mm, SA334, triangular pitch 71.25 mm, 2917 tubes (pitch and count assumed)
ShellsChannel ID 4230, t = 90 mm, SA537. Lower shell ID 4250, 70 mm hub, 1:3 taper, 34 mm shell, SA516. 3000 mm to the mid-plane (assumed)
Model30 degree sector with cyclic symmetry; 143 924 nodes, 111 612 C3D8I solids; outer 4 tube rows as B31 PIPE beams, other tubes as truss links
LoadTube-side pressure on the tubesheet, holes, grooves and channel, channel end-cap thrust, increased proportionally to 26 MPa (30 MPa large deformation)
MaterialsEPP; bilinear Et = 0.1E; multilinear ASME VIII-2 Annex 3-D; isotropic, linear kinematic and combined (3 backstresses) hardening
CriteriaEPP limit load, twice elastic slope, tangent intersection, plastic work curvature (peak and 10%), 5% plastic strain, numerical instability
SolverAbaqus/Standard 2024, 4 cores, about 25 minutes per small-deformation hardening case, up to about 55 minutes in large deformation

Pre-processing in Abaqus/CAE: model, mesh, loads

All pictures in this section are screenshots of the delivered heat_exchanger_tubesheet.cae, which holds one model per analysis case.

Abaqus/CAE screenshot of the fixed tubesheet heat exchanger model: 30 degree sector of the tubesheet, channel shell, lower shell and tubes, coloured by section
Abaqus/CAE: 30 degree sector of the tubesheet, channel shell, lower shell and tubes, coloured by section

Every tube hole of the sector is modelled in the perforated plate, with six element layers through the thickness. The rim is tied to the perforated plate, and the mesh is refined to 5 mm around the grooves, where the plastic mechanism forms.

Abaqus/CAE screenshot of the fixed tubesheet heat exchanger model: perforated tubesheet with every tube hole of the sector, top view
Abaqus/CAE: perforated tubesheet with every tube hole of the sector, top view
Abaqus/CAE screenshot of the fixed tubesheet heat exchanger model: hex mesh around the tube holes, the rim and the grooves
Abaqus/CAE: hex mesh around the tube holes, the rim and the grooves
Abaqus/CAE screenshot of the fixed tubesheet heat exchanger model: r-z section of the shell junction with both grooves, where the collapse mechanism forms
Abaqus/CAE: r-z section of the shell junction with both grooves, where the collapse mechanism forms

Tube-side pressure acts on the tubesheet face, the hole walls, the grooves and the channel. The channel head is replaced by its pressure thrust, and the tube-end loads by nodal forces. Both cut planes carry cyclic symmetry; tubes and lower shell are supported at the exchanger mid-plane. In large deformation the tube links are replaced by axial simple supports, as the paper does.

Abaqus/CAE Load module: tube-side pressure and boundary conditions on the whole model
Abaqus/CAE Load module: tube-side pressure and boundary conditions on the whole model
Abaqus/CAE screenshot of the fixed tubesheet heat exchanger model: pressure on the hole walls and the tubesheet face, symmetry on the cut faces
Abaqus/CAE: pressure on the hole walls and the tubesheet face, symmetry on the cut faces

Results in Abaqus/Viewer

The elastic-perfectly plastic analysis stops converging at 11.41 MPa. Plastic strain concentrates at both grooves and forms a shear band across the rim between them, the same mechanism the paper shows. The perforated plate stays essentially elastic.

Abaqus result contour of the fixed tubesheet heat exchanger: elastic-perfectly plastic limit load 11.41 MPa, equivalent plastic strain at the last converged increment
Abaqus/Viewer: elastic-perfectly plastic limit load 11.41 MPa, equivalent plastic strain at the last converged increment
Abaqus result contour of the fixed tubesheet heat exchanger: the collapse mechanism, a shear band across the rim from groove to groove
Abaqus/Viewer: the collapse mechanism, a shear band across the rim from groove to groove

With bilinear hardening the structure keeps carrying load past the limit load. At 11.7 MPa plasticity is confined to the groove roots; at 22 MPa it spreads through the rim, and the 34 mm lower shell yields in membrane tension.

Abaqus result contour of the fixed tubesheet heat exchanger: bilinear hardening at 11.7 MPa, plastic strain at the groove roots
Abaqus/Viewer: bilinear hardening at 11.7 MPa, plastic strain at the groove roots
Abaqus result contour of the fixed tubesheet heat exchanger: bilinear hardening at 22 MPa, plastic strain spreading through the rim
Abaqus/Viewer: bilinear hardening at 22 MPa, plastic strain spreading through the rim
Abaqus result contour of the fixed tubesheet heat exchanger: von Mises stress at 20.8 MPa in the r-z section of the junction
Abaqus/Viewer: von Mises stress at 20.8 MPa in the r-z section of the junction
Abaqus result contour of the fixed tubesheet heat exchanger: deformed shape at 26 MPa, displacement magnitude, scale factor 10
Abaqus/Viewer: deformed shape at 26 MPa, displacement magnitude, scale factor 10

Validation against the paper: what matches and what does not

Paper value / Abaqus value (difference), in MPa. Small deformation, Tables 2 and 3 of the paper.

CasePWC max curvaturePWC 10%Tangent intersection5% plastic strainTwice elastic slope
Bilinear isotropic12.80 / 12.54 (-2.0%)15.00 / 12.84 (-14.4%)15.90 / 13.76 (-13.5%)21.00 / 19.75 (-6.0%)22.00 / 14.83 (-32.6%)
Multilinear isotropic14.30 / 13.78 (-3.7%)17.60 / 14.59 (-17.1%)16.50 / 16.49 (-0.1%)13.30 / 12.14 (-8.7%)16.40 / 11.43 (-30.3%)
Bilinear kinematic12.70 / 12.54 (-1.3%)17.00 / 12.84 (-24.5%)16.90 / 13.76 (-18.6%)24.00 / 19.95 (-16.9%)21.90 / 14.82 (-32.3%)
Multilinear kinematic14.20 / 11.61 (-18.3%)18.20 / 16.06 (-11.7%)15.40 / 14.29 (-7.2%)12.99 / 12.14 (-6.6%)15.70 / 11.36 (-27.7%)
Other checksPaperAbaqusDifference
EPP limit load11.7011.41-2.4%
Bilinear, large deformation: PWC max curvature13.1213.50+2.9%
Bilinear, large deformation: numerical instability24increment cut-back at 24.4, completes to 30–
Multilinear, large deformation: PWC max curvature13.709.14-33.3%
Multilinear, large deformation: numerical instability21.016.18-23.0%
Every plastic-load criterion and material case: paper against Abaqus with signed differences
Every plastic-load criterion and material case: paper against Abaqus with signed differences
Signed deviation from the paper for every criterion, with the 10 percent band
Signed deviation from the paper for every criterion, with the 10 percent band
  • Limit load and mechanism: 11.41 against 11.7 MPa (-2.4%), the same groove-to-groove shear band.
  • Plastic work curvature: -1.3% to -3.7% for bilinear isotropic, bilinear kinematic and multilinear isotropic; +2.9% for bilinear in large deformation.
  • 5% plastic strain: -6.0% to -8.7% in three of four cases. For bilinear kinematic the paper gives 24 MPa against 21 MPa for isotropic; Abaqus gives nearly the same load for both (19.95 and 19.75), as expected for monotonic proportional loading.
  • Twice elastic slope, about 30% low in every case: the 34 mm lower shell carries the tube-bore pressure force at about 13.2·P MPa and yields in tension; its stretch dominates the groove displacement the criterion is read from. A diagnostic run with an elastic lower shell (included) cuts that displacement at 26 MPa from 27.4 to 7.4 mm. The paper’s own displacements are not self-consistent (9.24 mm at 11.7 MPa, 13.12 mm at 22 MPa), so displacement is not used as a target.
  • Multilinear large deformation: convergence is lost at 16.2 MPa against 21 MPa (15.3 MPa with tube links instead of simple supports).
  • Peak plastic strain at a given load is 43% to 77% higher than the paper’s, from the much finer groove mesh.
Load against groove-node displacement with the twice-elastic-slope and tangent-intersection constructions and the paper values
Load against groove-node displacement with the twice-elastic-slope and tangent-intersection constructions and the paper values
Plastic work curvature criterion for bilinear and multilinear hardening, Abaqus against the paper
Plastic work curvature criterion for bilinear and multilinear hardening, Abaqus against the paper

What is in the download

  • Abaqus/CAE 2024 file heat_exchanger_tubesheet.cae with 7 models: EPP limit, bilinear and multilinear with isotropic and kinematic hardening, bilinear and multilinear in large deformation.
  • Input decks (run_*.inp) of the 7 validation cases, the elastic check and the elastic-lower-shell diagnostic, plus the shared mesh.inp.
  • Key result images: the limit-load and 22 MPa plastic strain contours, the load-displacement curve and the comparison table, plus a short README.
  • PDF tutorial (separate download) covering the model, assumptions, criteria, results, the known differences and how to read every plastic load in Abaqus/Viewer.

No ODB files are included (about 1.7 GB each); every result can be regenerated from the decks.

Requirements: Abaqus/Standard and Abaqus/CAE 2024 or newer; a 4-core licence is enough.

Also available in Ansys MAPDL

The same tubesheet, rebuilt and solved in Ansys Mechanical APDL 2024 R2 with all hardening cases and cross-checked against this Abaqus model (23 of 31 criterion values within 5 %): Fixed tubesheet heat exchanger plastic load in Ansys MAPDL.

Need more than the files?

There are two ways we can help. Book a one hour online consultation if you want to talk a problem through with a CAE engineer, using the checkbox in the order box. Order a project if you need a full simulation built for you, delivered to an agreed scope, price and deadline under a written contract.

We work on FEA and CFD for engineers, researchers and companies. Order your project, or message us on WhatsApp for a quick reply.

Course Content

Product files

  • Abaqus CAE + INP model files, result images, README
  • Tutorial document (PDF)

Reviews

No Review Yet
No Review Yet
€99,00
Optional extras

Need a full custom project? See the options below.

23 people watching this product now!

Material Includes

  • PDF tutorial
  • Abaqus/CAE 2024 file with 7 models
  • Input decks of all cases and the shared mesh
  • Key result images and a short README

Audience

  • Pressure vessel and heat exchanger engineers using ASME VIII-2 design by analysis
  • FEA engineers who need a benchmark for limit and plastic load evaluation
  • Researchers and students of plastic collapse criteria

Related  Products

See more

Want to receive push notifications for all major on-site activities?

✕