About Course

Internal ring stiffeners are used in circular hollow section (CHS) joints in offshore jackets and other tubular steel structures. This Ansys example shows how to set up furnace heating and compare the resulting steel temperatures with two full-scale tests. It compares an unstiffened joint, SP-T1, with a joint reinforced by three internal rings, SP-T2.

Ring buckling and joint failure in Ansys

In the Ansys reproduction of the paper’s Fig. 22 case, the chord wall indents under the brace and the two outer rings fold out of plane. The central saddle ring stays nearly straight. The cutaway shows the solved mesh at true deformation scale.

Native Ansys cutaway of the FE-SP-T39 joint showing two folded outer rings beneath the brace
Converged Ansys cutaway after 1,704 s of fire exposure. Relative chord indentation is 20.7 mm and the peak-to-peak axial warp of each outer ring is 19.9 mm.

Internal rings before and during heating

Ansys mesh of the three internal rings after preload and before the fire
After preload. The three ring sections are nearly straight.
Ansys ring-only view showing localized folds in both outer rings and a nearly straight centre ring
During fire, at 1,704 s. The folds remain visible with the surrounding chord hidden.

Comparison with the paper

FE-SP-T39 is the paper’s Section 4 parametric configuration with a 400 mm chord, fixed chord ends and 169.1 kN of brace compression during ISO 834 heating. Both Ansys meshes reach 12 mm of relative chord indentation at a crown temperature of about 699 °C. The corresponding benchmark in Fig. 24 is about 714 °C. In both meshes, the outer-ring warp is about 15.2 mm at 1,680 s.

Ansys curve of chord indentation versus crown temperature and histories of axial warp in the three rings
The left plot compares the 12 mm chord indentation criterion with the paper. The right plot shows the growth of local axial warp in the two outer rings.

For the reference failure shape, see Fig. 22 in Chen, Shao and Yang (2015). The SP-T1 and SP-T2 furnace-test models below are a separate comparison.

Paper title and abstract summary

Study on fire resistance of circular hollow section (CHS) T-joint stiffened with internal rings

Chen, Shao and Yang tested two full-scale CHS T-joints, one unstiffened and one reinforced with internal rings. They applied a constant compressive load to each brace and heated the joints in an electric furnace until failure. The authors reported that the rings limited chord heating and increased the time to failure. They compared sequentially coupled thermal and structural models with measured temperatures and displacements at the crown, saddle and brace end, then used those models to study how ring dimensions and tubular diameter ratios affect fire resistance and failure mode.

C. Chen, Y.B. Shao and J. Yang, Thin-Walled Structures, 92, 104–114 (2015). Read the paper and its failure-mode figures.

Ansys pre-processing

The furnace-test model uses solid elements for the steel chord, brace, end plates and rings. The chord is 325 mm in outside diameter with a 6 mm wall. The brace is 159 mm in outside diameter with a 6 mm wall. SP-T2 has two crown rings and one saddle ring. The test fixture supports the chord ends, and the furnace test applies a sustained 98.4 kN compressive load at the brace end.

Ansys solid mesh of the chord, brace and end fixtures of specimen SP-T2
SP-T2 assembly mesh. The end fixtures and the brace loading end are visible.
Ansys longitudinal section exposing the two crown rings and central saddle ring in specimen SP-T2
SP-T2 longitudinal section before loading. The cut exposes all three internal rings.

Heat-transfer formulation

The transient conduction equation is ρcp∂T/∂t = ∇·(k∇T), where ρ is density in kg/m3, cp is specific heat in J/(kg·K), k is thermal conductivity in W/(m·K), and t is time in seconds. The exposed surface receives q = h(Tair − T) + εσ(Tcoil4 − T4), in W/m2. The radiation term uses absolute temperatures in K. The model uses h = 25 W/(m2·K) and effective emissivity ε = 0.7.

Ansys temperature contours

Native Ansys contour of the temperature field in unstiffened SP-T1 after 780 seconds
Native Ansys temperature contour for SP-T1 after 780 s of heating.
Native Ansys contour of the temperature field in ring-stiffened SP-T2 after 1800 seconds
Native Ansys temperature contour for SP-T2 after 1,800 s of heating. The legend is specific to this figure.

Paper versus Ansys temperature histories

The comparison uses temperatures at the crown, saddle and brace over the shared furnace-test time range. The root-mean-square errors against the plotted test histories were 10.8–23.9 °C for SP-T1 and 17.0–23.4 °C for SP-T2.

Paper and Ansys temperature versus heating time at the crown, saddle and brace for SP-T1 and SP-T2
Comparison with the measured and published finite element temperature histories in Fig. 18 of Chen, Shao and Yang.

For a related tubular-joint example, see the Ansys offshore tubular T-joint stress concentration study.

Need more than the files?

There are two ways we can help. Book a one hour online consultation if you want to talk a problem through with a CAE engineer, using the checkbox in the order box. Order a project if you need a full simulation built for you, delivered to an agreed scope, price and deadline under a written contract.

We work on FEA and CFD for engineers, researchers and companies. Order your project, or message us on WhatsApp for a quick reply.

Course Content

Reviews

No Review Yet
No Review Yet
€0,00
Optional extras

Need a full custom project? See the options below.

25 people watching this product now!

Related  Products

See more

Want to receive push notifications for all major on-site activities?

✕