Ansys CT Fracture Specimen Model: Stress Intensity and J-Integral at Five Crack Lengths (LPBF Ti6Al4V)

€49,00
Optional extras

Need a full custom project? See the options below.

€49,00
Optional extras

Need a full custom project? See the options below.

21 people watching this product now!

Material Includes

  • PDF tutorial document (4 pages)
  • 5 MAPDL input decks (crack tip at 8, 12, 14, 17 and 20 mm)
  • Saved MAPDL database, result images and a results summary

Audience

  • Analysts who want a working Ansys CT fracture setup to adapt
  • Students learning the MAPDL contour-integral workflow on a 3-D specimen

What You Will Learn?

  • Run a 3-D compact-tension crack model in Ansys MAPDL at five crack lengths.
  • Extract KI and the J-integral along the crack front with CINT.
  • See how the model was checked against the ASTM E399 formula and a mesh study.
  • Know exactly what is and is not validated against the paper.

About Course

A compact-tension (CT) crack specimen in Ansys Mechanical APDL, set up for stress intensity factor (KI) and J-integral extraction at five crack lengths. The geometry and load follow the LPBF Ti6Al4V specimen of Sun et al., Aerospace 2025, 12, 103 (open access, CC BY): 62.5 x 60 x 10 mm block, 5,190 N maximum load, E = 102 GPa. You get five ready-to-run input decks, the saved database, result images and a 4-page PDF tutorial.

What this is, and is not. It is a verified, mesh-converged static model of a straight stationary crack with no residual stress. It is not a validated replication of the paper: it does not include residual stress, crack growth or fatigue life, and our result is about 17 % above the paper curve at the matching crack length (details below).

What you get

  • CT_baseline.apdl (crack tip 12 mm from the load line) and CT_a08, CT_a14, CT_a17, CT_a20.apdl (8, 14, 17 and 20 mm). Each is a self-contained MAPDL input: it builds, solves and writes KI, KII, KIII and J along the crack front. No Python or external mesh file is needed.
  • CT_baseline.db: the saved database of the baseline model.
  • Result images and a results summary with every assumption stated.
  • PDF tutorial (4 pages): prepare and solve, verification and convergence, and the paper comparison.

Model at a glance

FeatureAnsys implementation
Mesh9,025 SOLID185 bricks, 11,424 nodes; mapped core and radial rings at the crack tip; 1.5 mm far field; 5 layers over the half-thickness
SymmetryQuarter model, about four times smaller than the full specimen
MaterialLinear elastic, E = 102,000 MPa (paper Table 4); Poisson ratio 0.34 (assumed)
Load5,190 N as a distributed bearing load on the upper pin semicircle; pins and contact are not modelled
OutputsKI along the front and J-integral (CINT, 8 contours), reaction check, stress field
Solve time10 to 40 seconds per deck on 4 cores
Ansys CT specimen quarter model: 9,025 SOLID185 bricks with radial crack-tip mesh, supports and pin load
The quarter model and the radial crack-tip mesh. Plots of the actual mesh, not Mechanical screenshots.

Results

Crack tip a (mm)KI centre (MPa√mm)KI thickness average
8316.2307.3
12 (baseline)392.5382.7
14434.0423.3
17502.0489.5
20581.9567.1

How it was checked

  • Against the standard CT formula. The same geometry solved in plane strain agrees with the ASTM E399 CT formula within 1 % for a/W of 0.34 and above (+0.8 % at a = 17 mm, 0.0 % at 20 mm). At shorter cracks it is up to 4.5 % higher, because the formula assumes a 12.5 mm pin hole and the model has 10 mm.
  • Thickness effect explained. The free 3-D specimen averages 1.06 times the plane-strain KI, equal to 1/√(1 − ν²) = 1.063, the plane-stress compliance factor.
  • Mesh convergence. Far-field size, crack-tip ring size and layer count each change the centre KI by less than 0.25 %.
  • Integral checks. J-derived KI is within 0.24 % of the contour KI; the reaction balances the applied load.
Ansys CT model verification: plane-strain check against the ASTM E399 formula, thickness effect, mesh convergence and paper comparison
Verification against the E399 formula, the thickness effect, mesh convergence and the paper comparison.

Comparison with the paper: open item

Reading Fig. 10(d) of the paper by eye gives about 335 MPa√mm at the centre line at 10 mm crack extension (our reading, about ±10, not author data). This model gives 392.5 at the matching crack length, about 17 % higher. The paper curve also rises more slowly than this model and the E399 formula, so a simple shift of the crack-length origin does not reconcile them. The paper does not publish the notch and pin dimensions, the crack-length origin or the crack-front shape. We therefore claim no validation against the paper. The straight crack and zero KII and KIII follow from the symmetry.

Not included

  • Residual stress or the LPBF manufacturing simulation
  • Crack growth, Paris-law cycling or an a-N curve
  • Explicit pins and contact
  • A certified ASTM E647 specimen; not for test certification

Who it is for

  • Analysts who want a working Ansys CT fracture setup with crack-tip mesh and KI and J extraction to adapt to their own specimen.
  • Students learning the MAPDL contour-integral workflow on a 3-D specimen.

Software and requirements

  • Ansys Mechanical APDL 2024 R2 (the version it was solved in). The model is small, about 9,000 elements.
  • Your own copy of the paper if you want to compare further.

FAQ

Does it reproduce the paper? No. It is a verified baseline of a straight stationary crack. It is about 17 % above the approximate paper value at the matching crack length, and the cause is open.

Do I need Workbench? No. Run /INPUT,CT_baseline,apdl in an empty working directory.

Is this a design result? No. It is a training and starting-point model and does not replace an assessment by a qualified engineer.

Need more than the files?

There are two ways we can help. Book a one hour online consultation if you want to talk a problem through with a CAE engineer, using the checkbox in the order box. Order a project if you need a full simulation built for you, delivered to an agreed scope, price and deadline under a written contract.

We work on FEA and CFD for engineers, researchers and companies. Order your project, or message us on WhatsApp for a quick reply.

Course Content

Product files

  • Ansys decks, database and results (complete package)
  • Tutorial document (PDF)

Reviews

No Review Yet
No Review Yet
€49,00
Optional extras

Need a full custom project? See the options below.

21 people watching this product now!

Material Includes

  • PDF tutorial document (4 pages)
  • 5 MAPDL input decks (crack tip at 8, 12, 14, 17 and 20 mm)
  • Saved MAPDL database, result images and a results summary

Audience

  • Analysts who want a working Ansys CT fracture setup to adapt
  • Students learning the MAPDL contour-integral workflow on a 3-D specimen

Related  Products

See more

Want to receive push notifications for all major on-site activities?

✕