A ready-to-open Abaqus model of a removable cover-plate header box for an air-cooled heat exchanger, with 3D cover, gasket and preloaded studs, and the ASME VIII Division 2 stress linearisation worked through on the side plate and tube sheet. The result is checked against a published MEng thesis.

Air-cooled heat exchangers sit in refineries, gas plants, petrochemical units and power stations, onshore and on offshore platforms. At each end of the tube bundle there is a header box, and in the removable-cover design its open face is closed by a thick plate held by a ring of studs through a gasket. Design-by-rule formulas treat the box walls as plates or as a rigid frame. They are fast, but they can not show how the flange, the gasket and the studs share the load. A 3D model can, and it is the route that the ASME VIII Division 2 design-by-analysis rules ask you to take when the rules do not cover the geometry.
This product is that model, built and documented so you can open it, check every setting, and change it for your own box.
The reference is L. Prinsloo, “A critical evaluation of the design of removable cover-plate header boxes for air-cooled heat exchangers”, MEng thesis, University of Pretoria, 2011. In our words: the thesis compares the usual design-by-rule methods and rigid-frame hand models for these boxes with 3D finite element analysis. It models a box with a bolted cover and a graphite gasket, preloads the studs, applies 1.0 MPa design pressure, and linearises the stress on lines through the side plates and tube sheet. It then uses those results to judge how well the simpler methods work. We reproduce the finite element part only (the chapters on the model and its results, PDF pages 73 to 107) and cite page numbers throughout. We do not copy any figure or table from it.

Plate thicknesses are the corroded values of the thesis: side plate 27 mm, end plate 17 mm, tube sheet 27 mm, flange 30 mm, cover 45 mm. Materials are SA-516 Gr 60 N for the bonnet and cover (E = 189 GPa, nu = 0.33), SA-193 B7 for the studs (200 GPa, 0.30) and graphite for the gasket (0.95 GPa, 0.30).
Each stud runs from the cover top face to the flange back face. Its two end nodes are connected to 15 mm bearing rings by distributing couplings, so the stud load is spread over the ring instead of landing on one node. Boundary conditions are symmetry on x = 0 and y = 0, and one corner point fixed in z to remove the rigid-body mode. Its reaction is 1e-7 N in both steps, a quick check that the loads balance.
The 7 mm mesh uses 232,875 tetrahedra with 356,764 nodes. The 10 mm mesh (114,299 elements) gives the same key result within about 0.5 %, so the mesh is converged for the quantity we compare. Two levels were run, which is a sensitivity check, not an extrapolated convergence study.

Bolt preload by thermal shrink. A stud of area A, modulus E and expansion coefficient alpha, cooled by dT, would carry E alpha dT A if held rigidly. In a compliant joint with a gasket it carries less, so each stud has its own temperature change: dT_i = dT_0 F_target / F_i, where dT_0 is the rigid-joint value, F_target = 172.4 MPa x 285 mm2 = 49.1 kN, and F_i is the force that stud carried in a first run. This restores the stated preload without using any thesis result as a target. Final stud forces are 46.96 to 50.02 kN.

Stress linearisation. For a line of thickness t with stress sigma(x) measured from the inner face:
Integration is by Simpson’s rule on 21 points, as in the thesis. The side-plate component is the hoop stress S33, the tube-sheet component is S22. Pressure-only stress is the operating result minus the seating result, which is valid because the model is linear.
The headline quantity is the hoop bending stress on the side plate at the flange junction (SCL1), the one the thesis itself uses for its mesh study.
The model reproduces the thesis’s side-plate hoop bending stress at the flange junction within 5 % in the seating case (-4.7 %) and the operating case (-0.9 %), while the pressure-only share is 6.1 % high, just outside the 5 % tolerance, and was not tuned.
The +6.1 % on the pressure-only share is outside our 5 % tolerance. We did not adjust anything to close it. That share depends on how stiff the flange to side plate corner is, and that corner holds three dimensions the thesis does not give: the weld size, the flange and cover width, and the gasket thickness. We assumed all three. Seating and operating agree, which points to the bolt and gasket path being right, but we have not proved that the corner assumptions explain the gap. If you have the real drawing, change those three first.
Other points of honesty:
Thesis values are plotted by us from the numbers in its Tables 6-7, 6-8 and 7-1 (PDF pages 83, 85 and 93). The thesis figure is not reproduced.


The contour plots below cap the legend at 150 MPa so the plate stresses can be read. Grey marks the small regions above the cap, under the nuts and around the bolt holes, where the stud load enters the flange through the couplings.




Take SCL1, the line through the 27 mm side plate at mid-length, 46 mm from the mating face. The model gives a nearly straight hoop-stress profile through the thickness. In seating the membrane part is -0.6 MPa and the bending is 72.8 MPa in magnitude. In operating they are 3.9 MPa and 115.9 MPa. Subtract and you get the pressure-only bending, 43.1 MPa. The package shows how to get these numbers from the results database with three small scripts, and the tutorial walks through each step.
.cae) and its input file (.inp) for the validated 7 mm run.hb_build_base.py) and the variant generator (make_variants.py).The solver results database is not included. It is large, and every number in the tutorial can be regenerated by running the job (about 7 minutes at 4 cores in our run).
.cae file. The model uses Abaqus/Standard.Other bolted-flange and design-by-analysis models from EngineeringDownloads.com are listed in the shop under Engineering Files.
Need more than the files?
There are two ways we can help. Book a one hour online consultation if you want to talk a problem through with a CAE engineer, using the checkbox in the order box. Order a project if you need a full simulation built for you, delivered to an agreed scope, price and deadline under a written contract.
We work on FEA and CFD for engineers, researchers and companies. Order your project, or message us on WhatsApp for a quick reply.
Other packages engineers working on this topic also download.
API 579 Example 4.2 in Abaqus: Corrosion Mapping of a Metal Loss Pressure Vessel
Creep Damage Analysis of a Welded Steam Pipe Branch in Abaqus: UMAT, HAZ Hex Mesh and Paper Comparison€149,00
API 579 Example 4.7 in Abaqus: Corroded Conical Transition, Level 3 FFSNeed a full custom project? See the options below.

€129,00
€179,00

€149,00
€119,00
€129,00
€149,00
See more
Want to receive push notifications for all major on-site activities?