Bolt pretension in Abaqus looks like a two-click job. Cut a surface through the shank, add a bolt load, type a force, run. Then one of two things happens, and both of them confuse people.
Either the bolt force sits at exactly the number you typed for the whole analysis, no matter what you do to the joint. Or it changes in the second step and you cannot tell whether that is the physics or a mistake.
Both are normal Abaqus behaviour. Which one you get depends on a single boundary condition on one node, and most tutorials skip it entirely. This guide covers the setup properly, explains that one setting, shows how much preload to apply, and lists the mistakes that quietly give you the wrong clamping force.
What a pre-tension section actually does
Abaqus does not stretch your bolt. It cuts it.
A pre-tension section is a surface that slices the shank into two halves, plus a pre-tension node that owns the cut. That node is not attached to any element, and its coordinates do not matter. It carries exactly one degree of freedom, DOF 1, which is the relative displacement of the two cut faces along the section normal.
So there are only two things you can do to it:
- Put a concentrated force on DOF 1, and you have prescribed the bolt force.
- Put a boundary condition on DOF 1, and you have prescribed the tightening adjustment, which is the turn-of-nut case.
Everything else is bookkeeping. For solid (continuum) bolts the section is a surface cutting the shank. For truss or beam bolts the section collapses to a point at the last node of the element, so you name the element instead of a surface.
One more detail that matters later: the section normal. For a surface-based section Abaqus computes an average normal pointing away from the elements that generated the surface. You can also give it directly.
Setting up bolt pretension in Abaqus/CAE
1. Partition the shank
Abaqus/CAE needs a real face to turn into the internal surface, so partition the bolt where the cut should be. Put it in the plain shank, between the clamped faces. Not under the head, not at the thread root, not inside a contact region. A cut inside a contact zone or at a stress concentration gives you a messy load path and poor convergence.
If you are working with an orphan mesh there is no geometry to partition, so you select element faces instead. Those faces must all come from elements on one side of the section. Hide the other half with a display group first, otherwise it is very easy to pick a mixed set.
2. Create a datum axis along the bolt
For a solid region you must give a datum axis, or an axis of a datum coordinate system, that points along the bolt. It does not have to be normal to the cross-section. For a 3D wire bolt you do not need one: the axis is the tangent to the wire at the cut.
3. Create the bolt load
Load module → Create Load → Step: the first analysis step → Category: Mechanical → Type: Bolt load. Select the partition face, then the datum axis, then pick the method:
- Apply force — you enter the bolt force in force units.
- Adjust length — you enter the change in free length, in length units.
Two limits worth knowing before you build the model. You can only create a bolt load in the first analysis step; in later steps you edit the one you already have. And bolt loads only work on 3D solid, 2D solid and 3D wire part instances. They are not supported on 2D or axisymmetric wire instances.
The same thing in the input file
If you prefer keywords, or you are editing the .inp directly, the whole setup is short:
*NODE 9001, 0., 0., 0. ** *SURFACE, NAME=BOLT-CUT, TYPE=ELEMENT SHANK-UPPER, S3 ** *PRE-TENSION SECTION, SURFACE=BOLT-CUT, NODE=9001 ** *STEP, NLGEOM=YES Tighten the bolt *STATIC 0.1, 1.0 *CLOAD 9001, 1, 137200. *END STEP
Node 9001 is the pre-tension node. It is declared in *NODE and used in no element. The force goes on DOF 1. For the length-adjustment method, replace the *CLOAD block with a prescribed displacement:
*BOUNDARY 9001, 1, 1, 0.16
The FOLLOWER parameter on *PRE-TENSION SECTION controls whether the normal is updated as the model deforms. FOLLOWER=YES updates it, FOLLOWER=NO keeps it fixed. This matters because Abaqus/CAE always writes a fixed normal. If your bolt rotates noticeably during the analysis, the input file is the only place you can turn follower behaviour on.
The step-2 decision that changes everything
This is where most bolt pretension models go wrong, and it is worth being very clear about.
Step 1 tightens the bolt. Step 2 applies the service load. What should happen to the bolt force?
In a real joint, a tightened bolt is a stiff spring. External tension partly unloads the clamped plates and partly adds force to the bolt, so the bolt force rises. If the plates settle, creep or yield locally, the bolt gives load back and the force drops. Bolt force is not constant once the wrench is off.
Abaqus will give you either behaviour, and you choose with one boundary condition:
| What you do in step 2 | What Abaqus holds fixed | What the bolt force does |
|---|---|---|
Nothing — leave the *CLOAD in place | the force | Stays exactly at the value you typed. The bolt stretches as far as it needs to. |
*BOUNDARY, FIXED on DOF 1(CAE: Fix at current length) | the length change reached at the end of step 1 | Changes with the response of the joint. This is the physical answer. |
The Abaqus documentation says it plainly: with the fixed condition in place, the fastener force can change in response to other loads to maintain equilibrium, and without a boundary condition the fastener force remains constant.
So read your own results this way:
- Bolt force never moves? You did not fix the length. Abaqus is acting as a constant-force jack, not as a bolt.
- Bolt force dropped a few percent in step 2? That is almost certainly correct. The clamped parts settled and the bolt released some load.
In keywords, the second step starts like this:
*STEP, NLGEOM=YES Service load *STATIC 0.05, 1.0 ** hold the tightening reached in step 1 *BOUNDARY, FIXED 9001, 1 ** now apply the external load *DLOAD ... *END STEP
In Abaqus/CAE: open the Load Manager, select the bolt load in the second step column, click Edit, and set Method to Fix at current length. That option only appears when you are editing a bolt load created in an earlier step, which is why people never find it while building step 1.
One related warning. If a pre-tension node has no load and no boundary condition in the first step, Abaqus issues a warning and you can end up with rigid body modes. That shows up as a numerical singularity or zero pivot at the pre-tension node, so it is worth knowing how to read the .msg file when a bolt job will not converge.
How much preload should you apply?
Take an M20 grade 8.8 bolt. Ultimate tensile strength fub = 800 MPa, tensile stress area As = 245 mm². For preloaded bolts, EN 1993-1-8 (Eq. 3.7) gives the preload as:
Fp,C = 0.7 · fub · As = 0.7 × 800 × 245 ≈ 137 kN
In an N, mm model that is 137200. on DOF 1. Check the code you actually have to satisfy, because ASME, AISC and EN each phrase preload differently, and some projects specify a snug-tight condition with no defined preload at all.
If you would rather prescribe the tightening adjustment, convert the force with the elastic stiffness of the clamped length:
δ = F · L / (E · A)
With a grip length L = 60 mm, E = 210 GPa and A = 245 mm², the 137 kN preload needs δ ≈ 0.16 mm. Note that L is the free length between the clamped faces, not the whole bolt. Using the full bolt length is a common way to over-tighten a model by a factor of two.
Torque is not an Abaqus input. If all you have is a torque spec, the usual estimate is T ≈ K · d · F with K ≈ 0.2 for plain steel threads, which puts 137 kN on an M20 at roughly 550 N·m. The K factor carries a lot of scatter, so if a preload force is available, use the force.
Reading the results without fooling yourself
Three output quirks catch people every time.
TF is the bolt force. Request TF as history output on the pre-tension node set. It is the reaction at the node plus any concentrated load there, acting along the section normal. Shear force across the section is not available from the pre-tension section.
U1 is not a displacement. At a pre-tension node, U1 is the tightening adjustment across the cut. It is not motion in space, so do not plot it as a deflection or include the node in a displacement contour.
The bolt will look shorter. In the deformed shape the underlying elements appear shortened even though the bolt is in tension, because that is how the cut is represented. It is not a bug and not a sign of a reversed normal.
If you need the stress distribution across the section itself, it is not directly available. Either read stresses in the elements on either side, or place a tied contact pair at the cut and read CPRESS and CSHEAR.
Common mistakes
- Cutting in the wrong place. Under the head, at the thread root, or inside a contact patch. Keep the cut in plain shank between the clamped faces.
- Forgetting the step-2 length fix. The single biggest source of wrong bolt force results. See the table above.
- Connecting the pre-tension node to something. It must be element-free, and it should not appear in an MPC. A linear
*EQUATIONis allowed, but an equation that links a section node to a node on the underlying side spans the cut and changes the pretension load. - A local coordinate system at the pre-tension node. Not permitted. You can use one at nodes that lie on the section, just not at the pre-tension node itself.
- Full preload applied while contact is still settling. Pretension pulls the clamped faces together, so if initial gaps and contact initialisation resolve in the same increment you get chatter. A short seating step, or contact stabilisation, fixes it.
- Substructures and submodels. Assembly loads cannot be defined inside a substructure, and a pre-tension section must lie entirely inside or entirely outside a submodel region. It must not cross driven nodes.
- Expecting it in Abaqus/Explicit. There is no pre-tension section in Explicit. See the FAQ below.
Ready-to-use bolted joint models
Reading about the pre-tension section is one thing; opening a model where it is already wired up correctly is faster. These are complete Abaqus models and packages you can run and reuse:
- Bolt Analysis Package in Abaqus — a collection of bolted joint models covering pretension, shear and tension failure in one package. The best starting point if bolts are a regular part of your work.
- Composite plate connection with a steel bolt under tension load — a pretensioned bolt clamping a composite laminate, which is the case where bolt force redistribution actually matters.
- Shear failure of two steel plates with a bolt connection — preload plus slip and bearing, with damage to failure.
- Dynamic bolt failure in a bolt and steel plates joint — the explicit-dynamics route, useful if you need bolt failure rather than a static clamping check.
If you want the wider picture first, the bolt analysis in Abaqus guide covers meshing, contact and material choices around the joint.
Frequently asked questions
Why does my bolt force change in the second step?
Because you fixed the bolt length, and that is correct. With *BOUNDARY, FIXED on DOF 1 (or Fix at current length in CAE), the tightening adjustment is held and the force is free to change so the joint stays in equilibrium. A real bolt behaves the same way. If the force never changes, you left the prescribed force active, and Abaqus is holding the force constant while letting the bolt stretch.
Can I apply bolt pretension in Abaqus/Explicit?
Not with a pre-tension section — that is an Abaqus/Standard feature. The usual workarounds in Explicit are a thermal contraction (give the shank a coefficient of expansion and apply a temperature drop that produces the right elongation) or an axial connector with a prescribed relative motion. Either way, ramp it over a long enough step to stay quasi-static, and check the kinetic energy. A cleaner option is to tighten in a Standard step and import the result into Explicit.
Force or length adjustment — which should I use?
Use a force when you have a preload specification, which is the common case. Use the length adjustment when you are modelling turn-of-nut, a measured elongation, or a bolt tightened to a known stretch. If the bolt rotates significantly during the analysis, prefer the force: with a fixed normal, a prescribed displacement under large rotation will not keep the fastener force steady.
Do I need to model the threads?
Not for clamping force. A plain shank with a tie or contact at the nut and head faces gives the right stiffness and the right bolt force. Model threads only when the question is local — stress at the first engaged thread, thread stripping, or fatigue at the thread root — and expect the mesh and run time to grow quickly.
Can I use more than one pre-tension section per bolt?
You need exactly one section per bolt, and each section needs its own pre-tension node. Do not share a node between bolts: you would be forcing them to the same adjustment. If a fastener is built from several segments, one section can be made from several surfaces, but it is still one cut and one node.
Summary
Bolt pretension in Abaqus is not complicated once you see what the pre-tension section is: a cut in the shank controlled by one node with one degree of freedom. Partition in plain shank, give a datum axis, apply the preload in step 1, and then make the deliberate choice in step 2 — fix the length if you want a bolt, leave the force if you want a jack. Read TF for force, treat U1 as an adjustment, and ignore the shortened bolt in the viewport.
If you would rather start from a model that already works, browse the ready-to-use Abaqus models and packages. And if you have a bolted joint that has to stand up to a code check or a client review, our team takes on custom simulation and consultation projects.
References: Abaqus Analysis User’s Guide, Prescribed assembly loads, and Abaqus/CAE User’s Guide, Understanding bolt loads.