Harmonic Response Analysis in ANSYS Workbench: A Practical Guide

Harmonic Response Analysis in ANSYS Workbench: A Practical Guide

Table of Contents

Your structure passed the static check. Then it went into service next to a pump, a compressor or a motor, and it started humming, cracking welds or loosening bolts. Static FEA will never show you that. You need a frequency-domain analysis, and in ANSYS that means a Harmonic Response system.

This guide covers harmonic response analysis in ANSYS Workbench the way it is actually set up in practice: what to link, what to type into Analysis Settings, how to choose damping, and the mistakes that quietly produce wrong answers.

What harmonic response analysis actually solves

A harmonic analysis assumes the load is sinusoidal and has been running long enough that all transients have died out. It solves for the steady-state response only. The equation being solved at each excitation frequency is:

[ K − ω2M + iωC ] {u} = {F}

Everything is complex. That is why every harmonic result has both an amplitude and a phase angle. The output is not a time history. A “Total Deformation” of 0.4 mm at 62 Hz means the part swings ±0.4 mm about its mean position at that frequency, not that it moved 0.4 mm once.

Two consequences people forget:

  • Harmonic response is a linear analysis. Plasticity, large deflection and separating contact are not solved.
  • Start-up, shutdown, run-up through a critical speed and impact events are transient problems. Harmonic will not capture them.

Always run a modal analysis first

A harmonic analysis without a preceding modal study is guesswork. The modal run tells you where the peaks are, so you know what range is worth sweeping and how fine the sweep has to be.

In the Workbench Project Schematic:

  1. Drag a Modal system onto the schematic.
  2. Drag a Harmonic Response system and drop it directly on the Solution cell of the Modal system. This shares geometry, materials, mesh and the modal results.

In the modal system, extract modes well past your top excitation frequency. A common working rule is to cover modes up to roughly 1.5 to 2 times the maximum frequency you intend to sweep. Modes just outside the window still contribute to the response inside it, and truncating them makes the amplitudes come out too low.

Check the mode shapes before going further. If the first mode is a rigid-body mode at ~0 Hz, your boundary conditions are wrong and nothing downstream will be meaningful.

Setting up the Harmonic Response system step by step

1. Frequency range and solution intervals

In Mechanical, select Analysis Settings:

  • Range Minimum / Range Maximum — the sweep window. Set it from the real excitation source: shaft speed, blade passing frequency, line frequency and their harmonics.
  • Solution Intervals — the number of equally spaced frequencies solved inside that window.

Interval count is where most harmonic runs go wrong. A lightly damped resonance peak is narrow. Its half-power bandwidth is approximately:

Δf ≈ 2ζfn

With 2% damping and a mode at 120 Hz, the peak is only about 4.8 Hz wide. If you sweep 0–500 Hz with 50 intervals, your step is 10 Hz and the solver can step straight over that peak. The plot then looks smooth and safe, and it is simply wrong.

Two fixes: raise the interval count, or switch on Cluster Results (Mode Superposition only), which concentrates solution points around each natural frequency instead of spacing them evenly.

2. Solution method: Mode Superposition or Full

Analysis Settings → Solution Method.

Mode Superposition (MSUP) expresses the response as a combination of the modes already computed. It is typically an order of magnitude faster, it allows Cluster Results, and it lets you apply damping per mode. It is the default choice for almost all structural work.

Full assembles and factorises the complete complex system at every frequency. It is slow, but it is the right choice for frequency-dependent material properties, unsymmetric matrices, or any case where mode truncation is unacceptable.

If you use MSUP and your loading is applied as base motion, enable Include Residual Vector. It adds a correction for the truncated higher modes and usually improves accuracy at low cost. ANSYS documents the trade-offs between the available methods in the Mechanical APDL Structural Analysis Guide.

3. Damping

Damping is not optional. With zero damping the computed response at resonance is limited only by the frequency step, so the peak value becomes meaningless — refine the sweep and the “stress” simply grows.

Under Analysis Settings → Damping Controls you have:

  • Constant Damping Ratio — a single ζ applied to all modes. Simple and usually adequate. Typical starting values: 0.01–0.02 for bolted steel structures, 0.005 or lower for a clean welded or machined part, 0.03–0.05 for assemblies with joints, gaskets or damping treatment.
  • Stiffness Coefficient (Beta) and Mass Coefficient (Alpha) — Rayleigh damping, where ζ(ω) = α/(2ω) + βω/2. Note that this makes damping frequency dependent: alpha damps low frequencies, beta damps high ones.
  • Constant Structural Damping Coefficient — hysteretic damping, independent of frequency. Common in rotordynamics and bolted-joint work.

If you have measured data, use it: the half-power bandwidth of a measured FRF gives ζ directly. If you have none, say so in your report and run a sensitivity study at 1%, 2% and 5%. The same choices exist in other codes — see damping in Abaqus.

4. Loads and phase

Right-click Harmonic Response → Insert and apply Force, Pressure, Remote Force, Moment or Acceleration. Each load carries its own Phase Angle field.

Phase matters as soon as you have more than one load: two forces at 0° add, the same two at 180° cancel. A rotating unbalance is modelled as two forces 90° apart with magnitude F = m e ω2. That magnitude grows with the square of the frequency, so use a tabular load following ω2, not a single constant force across the sweep.

For base excitation (shaker table, floor-borne vibration), apply Acceleration rather than fixing the base and pushing the part.

5. Reading the results

Insert results in this order:

  1. Frequency Response → Deformation (or Stress) scoped to a vertex or small face. This gives the amplitude-versus-frequency curve. Use it to find which frequencies actually matter.
  2. Phase Response on the same scoping, to see the 180° phase flip that confirms a true resonance.
  3. Total Deformation or Equivalent Stress, with the Frequency and Phase Angle fields set to the peak you identified in step 1. Only then do you get a contour plot that means something.

The contour is an amplitude. A fatigue check needs stress range, so 40 MPa amplitude is an 80 MPa range, and static mean stress has to be added separately before any Goodman or Haigh correction.

Prestressed harmonic response

Tension stiffens a structure and raises its natural frequencies; compression lowers them. A spinning disc, a tensioned cable, a pressurised vessel and a preloaded bolted joint all behave differently loaded than unloaded.

The chain is Static Structural → Modal → Harmonic Response, linking each Solution cell to the next Setup cell. Skip the static system on a preloaded structure and your resonance frequencies will be off — in a narrow sweep, enough to miss the peak completely. ANSYS covers the supported configurations in the Workbench harmonic response documentation.

Common mistakes

  • Too few solution intervals. The single most common error. The sweep steps over the peak and the result looks safe.
  • No damping, or damping copied from an unrelated model. Peak amplitude scales roughly as 1/(2ζ), so getting ζ wrong by a factor of five gets your stress wrong by a factor of five.
  • Not enough modes extracted. If the modal run stops at the top of the sweep range, the response near that limit is underestimated.
  • Expecting nonlinear contact to work. Contacts are linearised: Rough and Frictional are treated as Bonded, and Frictionless is treated as No Separation. If gapping or sliding is physically important, harmonic is the wrong tool.
  • Reading amplitude as peak-to-peak. It is not. Double it for range.
  • Feeding harmonic stress straight into a fatigue tool. Add mean stress and account for the number of cycles at each frequency. See our notes on the ANSYS Fatigue Tool.
  • Using harmonic for random excitation. Road, wind and flow-induced loading is broadband and needs a PSD-based random vibration analysis instead, as described in our random vibration guide.

Ready-to-use models

If you learn faster from a working model than from a blank Workbench project, these packages from the Engineering Downloads library cover the same physics end to end:

FAQ

What is the difference between modal and harmonic response analysis?

Modal analysis finds the natural frequencies and mode shapes of a structure with no applied load. It tells you where the structure is sensitive. Harmonic response applies a real sinusoidal load and tells you how large the deflection and stress actually get at each frequency. Modal is the screening step; harmonic gives you numbers you can compare against an allowable.

How many solution intervals should I use in ANSYS harmonic response?

Enough that several points land inside each resonance peak. Estimate the peak width as Δf ≈ 2ζfn and aim for three to five solution points inside that bandwidth. With Mode Superposition, Cluster Results does this automatically and is usually the better option.

Mode Superposition or Full method: which should I use?

Mode Superposition for most structural problems. It is far faster, supports Cluster Results and allows per-mode damping. Switch to Full when you have frequency-dependent material properties, unsymmetric matrices, or a case where mode truncation is unacceptable.

Why is my harmonic response stress enormous?

Almost always damping. With zero or very small damping, the response at resonance is limited only by how close a solution point lands to the exact natural frequency. Set a realistic damping ratio and re-run. If the stress is still high, the structure really does have a resonance inside the excitation range and needs to be detuned or damped.

Can I run a harmonic analysis with nonlinear contact or plasticity?

No. Harmonic response is a linear analysis. Contacts are linearised and material nonlinearity is ignored. If separation, sliding or yielding drive the behaviour you care about, use a transient structural analysis instead and accept the much longer run time.

Conclusion

Harmonic response analysis in ANSYS Workbench is not difficult to set up, but it is easy to set up in a way that produces confident-looking nonsense. Run modal first, extract enough modes, use a damping value you can defend, resolve the peaks properly, and read the results as amplitudes rather than displacements.

If you want a working model to study rather than a blank project, browse the vibration and dynamics packages in the Engineering Downloads shop. If something is vibrating in service and you need the analysis done properly, our simulation and consultation services cover modal, harmonic and transient dynamic work, and long sweeps on large models run well on our HPC service.

Leave a Reply

Your email address will not be published. Required fields are marked *

Related  articles

Abaqus Integration Point vs Nodal Stress: Why Peaks Differ
Compare integration-point, element-nodal and unique-nodal stress in Abaqus, and check whether a contour peak depends on extrapolation, averaging or mesh size.
Abaqus Linear Perturbation vs General Step: What Actually Changes
Abaqus Linear Perturbation vs General Step: What Actually Changes

You run a frequency extraction after a static step and the frequencies come out the same whether or not the part had yielded. You run a static linear perturbation step and the reaction force is a fraction of what you

Harmonic Response Analysis in ANSYS Workbench: A Practical Guide
Harmonic Response Analysis in ANSYS Workbench: A Practical Guide
How to set up harmonic response analysis in ANSYS Workbench: modal link, frequency range, solution method, damping, loads and results, plus the common mistakes.

See more

Related  Products