Abaqus Units: How to Set Up a Consistent Unit System

Abaqus Units: How to Set Up a Consistent Unit System

Table of Contents

You run a steel model, open the ODB, and the stresses come out at 108 MPa. Or the first natural frequency is 0.4 Hz for a part that should ring at 400 Hz. Nothing in the solver crashed. Nothing warned you. The model is simply wrong, and almost always the cause is the same: Abaqus units.

Abaqus does not know what a millimetre is. It multiplies the numbers you type. If those numbers come from four different unit systems, you still get a clean job and a convincing colour plot. This guide gives you the consistent unit tables, the real values for steel, the thermal units most guides skip, and three checks that catch a unit error in about five minutes.

Why Abaqus has no unit system

Abaqus is unitless by design. The Abaqus Analysis User’s Guide states it plainly: there is no built-in system of units, and you must not type unit labels with your data. You pick a system before you build the model, and every single number must belong to it.

A unit system is consistent when force equals mass times acceleration with no hidden conversion factor. That is the whole rule. Length, mass and time are free choices; force, stress, energy and density then follow from them. You cannot choose stress in MPa and mass in kilograms and expect the solver to reconcile them.

This matters more in Abaqus than in some other codes because so much of a real model comes from outside: CAD geometry in millimetres, a material card from a paper in SI, a pressure from a datasheet in bar, a film coefficient from a textbook in W/m²K. Each one is a chance to break consistency.

The four consistent unit systems

These are the four sets given in the Abaqus documentation. Pick one and stay in it.

QuantitySISI (mm)US (ft)US (inch)
Lengthmmmftin
ForceNNlbflbf
Masskgtonne (103 kg)sluglbf·s²/in
Timessss
StressPa (N/m²)MPa (N/mm²)lbf/ft²psi (lbf/in²)
EnergyJmJ (10−3 J)ft·lbfin·lbf
Densitykg/m³tonne/mm³slug/ft³lbf·s²/in⁴

Two things trip people up here. The mass unit in the mm system is the tonne, not the kilogram. And the mass unit in the inch system is lbf·s²/in, which is 12 slugs — some people call it a slinch. Neither is the unit you would naturally type.

Steel and aluminium in the mm–tonne–second system

Most structural work ends up in millimetres because that is what the CAD arrives in. Here are the numbers you actually need.

PropertySI (m, kg, s)SI (mm, tonne, s)
Steel density7850 kg/m³7.85e-9
Aluminium density2700 kg/m³2.7e-9
Concrete density2400 kg/m³2.4e-9
Steel Young’s modulus2.1e11 Pa210000
Aluminium Young’s modulus7.0e10 Pa70000
Gravity9.819810
Pressure of 1 bar1.0e50.1
Pressure of 1 psi68950.006895

For the inch system, steel density is about 7.35e-4 lbf·s²/in⁴, Young’s modulus about 3.05e7 psi, and gravity is 386.1 in/s². The Abaqus manual adds a warning worth repeating: handbook densities in US units are sometimes already multiplied by g, so check whether you have mass density or weight density before you type it.

Thermal and heat transfer units

This is where most unit guides stop, and it is where welding, additive manufacturing and thermal–stress models usually go wrong. Conductivity happens to keep the same number in the mm system, which gives people false confidence — specific heat does not.

PropertySI (m, kg, s)SI (mm, tonne, s)Factor
Conductivity, steel45 W/(m·K)45×1
Specific heat, steel460 J/(kg·K)4.6e8×106
Film coefficient25 W/(m²·K)0.025×10−3
Heat flux1.0e6 W/m²1.0×10−6
Latent heat, steel2.7e5 J/kg2.7e11×106
Stefan–Boltzmann5.67e-85.67e-11×10−3

The reason specific heat carries a factor of 106 is that energy shrinks by 103 (J to mJ) while mass grows by 103 (kg to tonne). The two do not cancel — they compound. If you type 460 in a mm model, your part has a thousandth of its real thermal mass and it will heat up and cool down far too fast. In a weld pass that looks like a temperature field that collapses between passes, which then gives you residual stresses that are completely wrong but not obviously wrong.

Three checks that catch a unit error

1. Query the model mass

In Abaqus/CAE go to Tools → Query → Mass properties on the part or the assembly. Compare the reported mass with a hand estimate. A 100 mm steel cube has a volume of 1e6 mm³, so in the mm system its mass must be 7.85e-9 × 1e6 = 7.85e-3 tonne, which is 7.85 kg. If the query says 7.85 or 7850, your density is in the wrong unit. This takes thirty seconds and catches the single most common mistake.

2. Check the self-weight reaction

Apply gravity as the only load in a static step and sum the reaction forces at the supports. The total must equal mass × g. For that same cube: 7.85e-3 tonne × 9810 mm/s² = 77 N. If you get 0.077 N you typed 9.81 instead of 9810. If you get 77000 N your density is off by 103.

3. Compute the wave speed

This is the fastest check for explicit models. Dilatational wave speed is roughly:

cd = √(E / ρ)

For steel in the mm system: √(210000 / 7.85e-9) = 5.17e6 mm/s, which is 5170 m/s. That is the right answer for steel. If you used 7.85e-6 by mistake you get 1.6e5 mm/s, or 163 m/s — slower than sound in air. Your stable time increment would then be 31.6 times too small and the job would take all night for no reason. If you are already fighting runtime in Abaqus/Explicit, check this before reaching for mass scaling.

Temperature, absolute zero and physical constants

Temperature is the one quantity Abaqus will not sort out for you. You can work in °C or in K, but radiation and any gas-law behaviour need absolute temperature, so the solver has to be told where zero is.

If you use °C and have any radiation interaction, set the physical constants:

*PHYSICAL CONSTANTS, ABSOLUTE ZERO=-273.15, STEFAN BOLTZMANN=5.67E-11

In CAE the same thing lives under Model → Edit Attributes → Physical Constants. The Stefan–Boltzmann value above is for the mm–tonne–second system; in SI it is 5.67e-8. Forget this and a radiation-dominated model will quietly give you nonsense, because the solver treats 20 °C as 20 K.

Thermal expansion coefficients are per degree and are the same number in both systems, which is one less thing to worry about. Coefficients taken from a reference at a non-zero datum temperature are a separate trap — set the reference temperature rather than assuming it is zero.

Common Abaqus units mistakes

  • Density in kg/mm³. Mass comes out 1000× too high, frequencies drop by a factor of about 31.6, and explicit runtimes explode.
  • Gravity as 9.81 in a mm model. Self-weight becomes a thousand times too small and the model looks suspiciously stiff.
  • Specific heat not converted. The 106 factor described above. Very common in welding and AM models.
  • Imported CAD in metres, material in MPa. Check the part’s bounding box with the query tool after every import.
  • Pressure typed in bar or psi. Convert first: 1 bar is 0.1 MPa, 1 psi is 0.006895 MPa.
  • Moments in N·m inside a mm model. A moment in the mm system is N·mm, so multiply by 1000.
  • Fracture toughness and energy release rate. J-integral comes out in mJ/mm² in a mm model, which is numerically the same as kJ/m². Convenient, but confirm it rather than assuming.
  • Two engineers, two systems. On shared projects, write the unit system in the model name and in the job description. It costs nothing and prevents a lot of rework.

If you want a deeper reference on the SI itself and how to convert cleanly, the NIST Guide for the Use of the International System of Units is the standard source.

Ready-to-use models and courses

The quickest way to internalise units is to open a model that already works and read its material card. A few places on Engineering Downloads to do that:

You can browse the full library of simulation files, packages and courses in the shop.

FAQ

Does Abaqus have a built-in unit system?

No. Abaqus is unitless and performs no conversions. You choose a consistent system, enter plain numbers with no unit labels, and interpret the results in that same system.

What density should I use for steel in an Abaqus mm model?

7.85e-9 tonne/mm³ for a density of 7850 kg/m³. For aluminium use 2.7e-9 and for normal concrete about 2.4e-9.

What value of gravity do I use in a millimetre model?

9810 mm/s². In the inch system it is 386.1 in/s², and in SI metres it is 9.81 m/s².

Can I mix unit systems in one Abaqus model?

No. Every length, mass, force, time, temperature and material property must belong to the same consistent system. There is no per-part or per-material unit setting to rescue a mixed model.

Why is my specific heat wrong in a mm–tonne–second model?

Because energy drops by 103 and mass rises by 103, so specific heat needs a factor of 106. A steel value of 460 J/(kg·K) becomes 4.6e8.

Conclusion

Units cause more silently wrong Abaqus results than any solver setting. The fix is cheap: choose one consistent system before you start, convert every imported number into it, and spend five minutes on the mass, self-weight and wave-speed checks before you trust a single contour plot.

If you would rather hand the whole model over, our team takes on custom simulation and consulting projects in FEA, CFD, fatigue, fracture and fitness-for-service. Or start from a verified model in the Engineering Downloads shop and build from something that already runs.

Leave a Reply

Your email address will not be published. Required fields are marked *

Related  articles

Abaqus Integration Point vs Nodal Stress: Why Peaks Differ
Compare integration-point, element-nodal and unique-nodal stress in Abaqus, and check whether a contour peak depends on extrapolation, averaging or mesh size.
Abaqus Linear Perturbation vs General Step: What Actually Changes
Abaqus Linear Perturbation vs General Step: What Actually Changes

You run a frequency extraction after a static step and the frequencies come out the same whether or not the part had yielded. You run a static linear perturbation step and the reaction force is a fraction of what you

Harmonic Response Analysis in ANSYS Workbench: A Practical Guide
Harmonic Response Analysis in ANSYS Workbench: A Practical Guide
How to set up harmonic response analysis in ANSYS Workbench: modal link, frequency range, solution method, damping, loads and results, plus the common mistakes.

See more

Related  Products

See more