If you run any elastic-plastic analysis in Abaqus, PEEQ is the result you will look at most. It tells you where the material has yielded and how much permanent strain it has picked up. It is also the variable people misread most often, usually by comparing it to the wrong limit or by trusting a contour value that only exists because the mesh has a sharp corner in it.
This guide explains what PEEQ in Abaqus actually is, how it differs from PE and PEMAG, how to request and plot it correctly, and how to decide whether a value is acceptable.
What PEEQ actually measures
PEEQ is the accumulated equivalent plastic strain. It is a single scalar built by integrating the plastic strain rate over the whole load history:
PEEQ = ∫ √(2/3 · dεpl : dεpl)
Two consequences follow from that integral, and both matter in practice:
- PEEQ never decreases. Unload the model and PEEQ stays where it is. Reverse the load and PEEQ keeps growing, because the increment is always positive.
- PEEQ is a damage-style counter, not a current state. It measures how much plastic work the point has been through, not how distorted it is right now.
That is exactly why PEEQ is the variable used in cyclic plasticity, ratcheting and code strain-limit checks. It accumulates.
PEEQ vs PE vs PEMAG vs LE
These four show up together in the Field Output menu and they are not interchangeable.
| Variable | What it is | Use it for |
|---|---|---|
| PEEQ | Accumulated equivalent plastic strain (scalar, monotonic) | Yield extent, code strain limits, cyclic accumulation |
| PEMAG | Magnitude of the current plastic strain tensor | How much permanent deformation is left in the part now |
| PE | Plastic strain tensor components (PE11, PE22, PE12 …) | Direction of yielding, anisotropy checks, post-processing |
| LE | Total logarithmic strain (elastic + plastic) | Comparing against measured strain, forming limits |
The one people get wrong: PEEQ and PEMAG are equal only under proportional loading. Load a bar in tension and then in compression, and PEMAG can drop back toward zero while PEEQ keeps climbing. If your model has reversed or non-proportional loading, pick the variable deliberately.
The Abaqus output variable definitions are in the element integration point variables section of the documentation.
How to request PEEQ in Abaqus
In Abaqus/CAE
Step module → Output → Field Output Requests → Edit F-Output-1 → open the Strains group → tick PE, PEEQ and PEMAG.
The preselected defaults for a general static step usually already include them. The problem is that people later switch the request to a custom list and drop PEEQ without noticing. Check the request before you submit a long job.
In the input file
*OUTPUT, FIELD, FREQUENCY=1 *ELEMENT OUTPUT S, PE, PEEQ, PEMAG, LE *NODE OUTPUT U, RF ** ** history output at one integration point *OUTPUT, HISTORY, FREQUENCY=1 *ELEMENT OUTPUT, ELSET=NOTCH-TIP PEEQ
Add a history output request at the hot spot. A PEEQ-versus-time curve tells you far more than a contour plot, especially for cyclic jobs where you want to see whether the strain is shaking down or ratcheting upward every cycle.
How to plot and read PEEQ correctly
- Visualization module → Result → Field Output, choose PEEQ as the primary variable.
- Turn averaging off first. Result → Options → Averaging, set the threshold to 0%, or plot a quilt contour. PEEQ lives at the integration points. Nodal averaging smears a peak across neighbouring elements and across material boundaries, which can hide or invent a hot spot.
- Look at the section points for shells. A shell can be fully elastic at the midplane and plastic at the surface. Check the top and bottom section points, not only the default one.
- Use Tools → XY Data → ODB field output to pull PEEQ along a path through the thickness. For pressure-vessel work that through-thickness profile is the real answer, not the surface contour.
One useful detail from the documentation: PEEQ also doubles as a yield flag for some material models, returning 1 or 0 to show whether the point is actively yielding at that increment.
How to judge whether a PEEQ value is acceptable
There is no universal “PEEQ must stay below X”. The limit comes from the code you are working to, the material, and the stress state.
Code strain limits depend on triaxiality
ASME VIII-2 Part 5 and API 579 Part 5 both use a local strain limit that gets smaller as the stress state becomes more triaxial. The form is:
εL = εLu · exp[ −(αsl / (1 + m2)) · ( (σ1+σ2+σ3) / (3σe) − 1/3 ) ]
The check is then a damage ratio: accumulated PEEQ divided by that local limit must stay at or below 1.0. Two points with the same PEEQ can pass and fail depending on how triaxial the local stress is, which is why a blanket percentage rule is meaningless. A weld root in a thick section is far less tolerant than a thin shell in membrane tension.
For background on how triaxiality-based strain limits behave and where they get stretched, the Los Alamos review Evaluation of Strain and Exhaustion Limits for Vessels is a good read, although it is written around Division 3 impulsively loaded vessels.
Plastic collapse is not a PEEQ check
This one costs people a lot of time. In an elastic-plastic limit load or plastic collapse analysis, the acceptance criterion is whether the solution converges at the required factored load. It is not a PEEQ threshold. PEEQ tells you where the plastic zone formed and whether it has gone through-thickness, which is useful supporting evidence, but the pass/fail is the load the model can carry.
PEEQ with UMAT and VUMAT
If your material is defined by a user subroutine, Abaqus does not know what part of your strain is plastic. With a UMAT, PEEQ is normally written out as zero. The same is true for a VUMAT in Abaqus/Explicit.
The fix is to accumulate the equivalent plastic strain yourself inside the subroutine, store it in a state variable, and output it as SDV:
C inside UMAT, after the return mapping
STATEV(1) = STATEV(1) + DEQPL
C
C request it in the input file
*DEPVAR
4
*OUTPUT, FIELD
*ELEMENT OUTPUT
S, LE, SDVRemember to declare enough state variables with *DEPVAR, and label the slot in your own notes, because SDV1 means nothing to anyone reading the ODB later. Fortran is the official language for Abaqus user subroutines, so plan the build environment around that.
If you are new to this, our UMAT vs VUMAT comparison explains which one fits your problem before you write any code.
Common mistakes with PEEQ
- Reading the peak value at a sharp re-entrant corner. A geometric singularity has no converged strain. Refine the mesh and the PEEQ peak keeps rising. Add the real fillet radius, or evaluate on a path a short distance away, and report that instead.
- Comparing PEEQ to the material elongation at fracture. Tensile elongation is a uniaxial, gauge-length-averaged number. Local PEEQ at an integration point is not the same quantity and the comparison is usually far too optimistic.
- Leaving averaging at 75%. The default smooths the one value you came to look at.
- Using PEMAG where the load reverses. After a full cycle PEMAG can look small while the part has accumulated real damage. Use PEEQ for anything cyclic.
- Forgetting that a perfectly plastic material will not stabilise. With no hardening, PEEQ grows until the solver gives up. If you are chasing non-convergence in a plastic model, check the hardening curve before you blame contact.
- Not checking the hardening curve range. Abaqus extrapolates the last point of the
*PLASTICtable as perfectly plastic. If PEEQ exceeds your last tabulated plastic strain, the response beyond that point is an assumption, not data.
Ready-to-use models that put PEEQ to work
Reading about plastic strain is one thing. Seeing it evaluated against a real code check in a working model is faster. These packages on Engineering Downloads all use elastic-plastic analysis and accumulated plastic strain in the way described above:
- ASME VIII Div.2 Part 5 Design by Analysis with Abaqus — plastic collapse, buckling and fatigue, including the strain-limit side of the assessment.
- API 579 Example 5.6 in Abaqus: Local Thin Area Limit Load — a Level 3 FFS limit-load case where convergence, not a strain number, is the criterion.
- Advanced Material Modeling in Abaqus with UMAT and VUMAT — how to accumulate and output your own equivalent plastic strain.
- Johnson–Cook plasticity parameters for Inconel 718 — plastic strain under high strain rate in Abaqus/Explicit.
You can browse the full library in the shop.
FAQ
What does PEEQ stand for in Abaqus?
PEEQ stands for equivalent plastic strain. It is the accumulated scalar measure of plastic straining at an integration point, built by integrating the plastic strain rate over the entire analysis history.
Why is my PEEQ zero everywhere?
Either the model never yielded, or the material has no plasticity definition, or you are using a UMAT or VUMAT. With a user subroutine material, Abaqus cannot separate elastic from plastic strain, so PEEQ stays at zero and you must output your own accumulated value as an SDV.
What is the difference between PEEQ and PEMAG?
PEEQ accumulates and never decreases. PEMAG is the magnitude of the current plastic strain tensor and can go up or down as the load reverses. They are equal only for proportional loading.
Is there a safe PEEQ limit, like 2% or 5%?
No general limit exists. Code limits such as those in ASME VIII-2 Part 5 and API 579 scale with stress triaxiality, so the allowable local strain at a thick weld root is much lower than in a thin shell under membrane tension. Always evaluate against the limit for the actual stress state.
Can I use PEEQ to judge plastic collapse?
Not directly. In an elastic-plastic collapse or limit-load analysis the criterion is whether the solution converges at the required factored load. PEEQ is useful supporting evidence about where the plastic hinge or through-thickness yielding formed.
Next step
PEEQ is simple once you treat it as a history counter rather than a stress-like contour: request it, plot it unaveraged, read it on a path instead of at a singular corner, and compare it only to a limit that accounts for triaxiality.
If you want a worked model where the strain check is already set up and documented, start with the ready-to-use Abaqus packages. If you have a vessel, pipe or welded component that needs a defensible elastic-plastic assessment, we also take on that work directly through engineering consultation and custom simulation.