Abaqus Field Output vs History Output: A Practical Guide

Abaqus Field Output vs History Output: A Practical Guide

Table of Contents

You run the job, open the ODB, and the stress contour looks great. Then you try to plot force against displacement and you get eleven points joined by straight lines. Or the opposite problem: the curve is perfect, but the ODB is 38 GB and your HPC quota is gone.

Both problems come from the same place. In Abaqus, field output and history output are two different output mechanisms with two different jobs, and most of us set them up once years ago and never looked again. This guide explains what each one actually does, how to request it properly, and how to stop them from either wrecking your post-processing or filling your disk.

Field output vs history output: the one-line difference

Field output is a snapshot of the whole model at a few moments in time. History output is a continuous curve for a few points in the model.

That is the whole idea. Field output exists so you can draw contour plots, deformed shapes and animations. History output exists so you can draw X-Y curves. If you ask the wrong one for the wrong job, you either get a jagged curve or an enormous file.

 Field outputHistory output
Spatial domainWhole model, or a large setA small node set, element set, surface or single point
Time resolutionCoarse: a handful of framesFine: typically every increment
What you do with itContours, animations, symbol plots, path plotsX-Y plots, load-displacement curves, convergence of a quantity
ODB costHigh. This is what fills your diskVery low, even at every increment
INP keyword*OUTPUT, FIELD*OUTPUT, HISTORY

Requesting field output without filling the disk

Field output is requested per step. In Abaqus/CAE: Step → Output → Field Output Requests → Create. Three settings decide whether your ODB is 200 MB or 40 GB.

1. Frequency, or number of intervals

In Abaqus/Standard you can write output every n increments (FREQUENCY=n) or at a fixed number of evenly spaced intervals (NUMBER INTERVAL=n). The second is almost always the better choice, because increment size changes during a nonlinear run and you have no idea in advance how many increments you will get. Ten or twenty frames is plenty for an animation.

In Abaqus/Explicit, frequency per increment is meaningless, because a typical run has hundreds of thousands of increments. Use NUMBER INTERVAL or a time interval there.

2. Variables

CAE’s preselected set is convenient but wide. On a static step it typically pulls S, PE, PEEQ, PEMAG, LE, U, RF, CF, CSTRESS and CDISP. If your study is about plastic strain, you do not need the contact variables, and if you are only checking a stress field you do not need four different strain measures.

A practical habit: start from the preselected set during model debugging, then trim it before the long production run.

3. Domain and position

Field output does not have to cover the whole model. If only the weld region or the crack region matters, request the heavy variables on that element set only, and keep U and RF for the whole model so the animation still looks right.

Position matters too. By default CAE writes integration point values. In the INP you can control it directly:

** Field output: whole model, 10 evenly spaced frames
*OUTPUT, FIELD, NUMBER INTERVAL=10
*NODE OUTPUT
U, RF
*ELEMENT OUTPUT, DIRECTIONS=YES
S, PE, PEEQ
**
** Heavy variables only on the region that matters
*OUTPUT, FIELD, NUMBER INTERVAL=10
*ELEMENT OUTPUT, ELSET=WELD-ZONE, POSITION=INTEGRATION POINTS
S, PEEQ, TEMP
**
** History output: one reference point, every increment
*OUTPUT, HISTORY, FREQUENCY=1
*NODE OUTPUT, NSET=LOAD-RP
U2, RF2

POSITION=AVERAGED AT NODES gives you smoother looking contours but hides the integration point scatter that tells you your mesh is too coarse. For a verification run, keep integration point values.

Requesting history output that is actually useful

History output is cheap, so there is no reason to be stingy with time resolution. The thing people get wrong is the domain.

History output needs a set. You cannot request history output for the whole model the way you do with field output, and that is deliberate: a curve per node for 400,000 nodes is not a curve, it is a second ODB. So before you create the request, create the node set or element set you will need. This is the one piece of pre-processing discipline that saves re-running a job.

Also worth knowing: CAE’s default history output request on a general static step is the whole-model energy history, not forces. That is genuinely useful for checking artificial energy, hourglass energy and whether an explicit run is behaving, but it is not what you need for a load-displacement curve. If you never touched H-Output-1, you have energies and nothing else.

Some quantities only ever exist as history output:

  • Contour integral results. J-integral, stress intensity factors and T-stress from a *CONTOUR INTEGRAL request come out as history output, one curve per crack front node per contour. There is no J contour plot.
  • LPF in a Riks analysis. The load proportionality factor is a history output quantity. Plotting LPF against the displacement of a monitored node is how you read a collapse curve.
  • Energies. ALLKE, ALLAE, ALLSE, ETOTAL and friends are history-only.
  • Integrated section forces. In Abaqus/Explicit, an integrated output section gives you SOF and SOM on a surface as history output, which is the clean way to get a total force.

The load-displacement curve, done properly

This is the case that generates most of the confusion, so it is worth doing step by step.

You can create X-Y data from field output in the Visualization module (Create XY Data → ODB field output). It works, but you only get one point per saved frame. If your field output is set to 10 intervals, your “curve” has 10 points. That is the jagged curve problem, and no amount of smoothing will fix it, because the data was never written.

The correct approach:

  1. Put the load or the displacement BC on a single reference point, tied to the loaded surface with a coupling constraint. Now one node carries the whole load.
  2. Create a node set containing that reference point.
  3. Create a history output request on that set, with U and RF in the loading direction, at every increment.
  4. In Visualization, Create XY Data → ODB history output, pick the RF and U curves, then Operate on XY Data to combine them with combine(U2, -RF2).

If you cannot use a reference point and your BC is spread over many nodes, request RF as history output for the whole loaded node set and sum the curves with sum(...) in Operate on XY Data. Do not read one node and assume it represents the total; it does not.

One more detail that catches people in displacement-controlled runs: the reaction force at a node with a prescribed displacement is the force the boundary condition applies, and its sign is opposite to the applied load direction. Hence the minus sign above. Always sanity-check the first few values against a hand calculation before you trust the whole curve.

Reading history output with Python

Clicking through the XY Data manager is fine once. For a parametric study it is not. History output is the easiest thing in the ODB to script, because it is already a list of time-value pairs:

from odbAccess import openOdb

odb  = openOdb('job.odb')
step = odb.steps['Step-1']

# Print the region keys first - the naming is not obvious
for key in step.historyRegions.keys():
    print(key)

region = step.historyRegions['Node ASSEMBLY.1']
u  = region.historyOutputs['U2'].data    # [(time, value), ...]
rf = region.historyOutputs['RF2'].data

with open('load_disp.csv', 'w') as f:
    for (t, disp), (t2, force) in zip(u, rf):
        f.write('%g,%g,%g\n' % (t, disp, -force))

odb.close()

Run it with abaqus python extract.py if you only need history output and no CAE kernel. The region key naming is the only real trap: an assembly-level reference point appears as Node ASSEMBLY.1, while a node inside an instance appears as Node PART-1-1.5. Print the keys once and hard-code what you find. There is more on the ODB object model in our guide to extracting Abaqus results with a Python script.

Common mistakes

  • Requesting field output every increment on a big model. This is the single biggest cause of a huge ODB. Switch to NUMBER INTERVAL.
  • Trying to plot a smooth curve from field output. The data points do not exist. Add a history request and re-run.
  • Forgetting to create the set before the request. CAE will not let you pick a set that does not exist, and people then default to a domain that is not what they wanted.
  • Leaving history output at the default energies. Useful, but not a force or a displacement.
  • Reading one node’s RF as the total reaction. Sum over the set, or use a reference point.
  • Setting output frequency to 0. FREQUENCY=0 suppresses output entirely for that step. Occasionally that is what you want on a long settling step; usually it is a typo you discover after an eight-hour run.
  • Not checking the .dat and .sta files first. If the job stopped early, the ODB is incomplete and no output request will fix it. The message and status files tell you why.

Ready-to-use models and courses

If you would rather learn this from working models than from doc pages, these packages on Engineering Downloads use field and history output exactly as described above:

If you want the INP side rather than the CAE side, the keyword workflow is covered in our guide to editing the Abaqus INP file.

FAQ

Can I plot a curve from field output in Abaqus?

Yes, with Create XY Data → ODB field output, but you only get one data point per saved frame. With a typical field output request of 10 to 20 intervals the curve is too coarse for anything quantitative. Use history output for curves.

Why is my Abaqus ODB file so large?

Almost always field output: too many variables, too many frames, or both, written over the whole model. Reduce the number of intervals, trim the variable list, and restrict the heavy element variables to the region you care about. History output is rarely the cause, even at every increment.

Why can I not request history output for the whole model?

Because history output writes one curve per point at every increment. Over a full mesh that would be larger than the field output it was meant to replace. Create a node set or element set containing only the points you want to monitor.

How do I get the total reaction force as history output?

Either apply the load through a single reference point coupled to the loaded surface and request RF there, or request RF for the whole loaded node set and sum the curves with sum(...) in Operate on XY Data. In Abaqus/Explicit, an integrated output section on a surface gives the total force (SOF) directly.

Is the J-integral field output or history output?

History output. A *CONTOUR INTEGRAL request writes J (or K, or T-stress) as one history curve per crack front node per contour. You cannot contour-plot J, which is why path independence is checked by comparing contours in an X-Y plot.

Getting it right the first time

Output requests are the cheapest part of an Abaqus model to get right and one of the most expensive to get wrong, because the fix is always a re-run. Two habits cover most of it: use NUMBER INTERVAL for field output instead of every increment, and create the monitoring sets and history requests before you submit, not after you see the results.

Official reference reading: the Abaqus documentation pages on the difference between field and history output and on understanding output requests.

Browse the full library of validated Abaqus and ANSYS models, scripts and courses in the Engineering Downloads shop. If you have a model that needs a second pair of eyes, or a post-processing pipeline you want automated, we also take that on through our engineering services.

Leave a Reply

Your email address will not be published. Required fields are marked *

Related  articles

Abaqus Integration Point vs Nodal Stress: Why Peaks Differ
Compare integration-point, element-nodal and unique-nodal stress in Abaqus, and check whether a contour peak depends on extrapolation, averaging or mesh size.
Abaqus Linear Perturbation vs General Step: What Actually Changes
Abaqus Linear Perturbation vs General Step: What Actually Changes

You run a frequency extraction after a static step and the frequencies come out the same whether or not the part had yielded. You run a static linear perturbation step and the reaction force is a fraction of what you

Harmonic Response Analysis in ANSYS Workbench: A Practical Guide
Harmonic Response Analysis in ANSYS Workbench: A Practical Guide
How to set up harmonic response analysis in ANSYS Workbench: modal link, frequency range, solution method, damping, loads and results, plus the common mistakes.

See more