You build a weld model, run it, and the whole weld bead sits there from the first increment — carrying stress before any metal was deposited. Or you model an excavation and the soil you were supposed to dig out keeps holding the wall up. Both problems have the same fix: Abaqus model change, the feature that switches elements off and on during an analysis.
Engineers also call it the birth and death method, or element activation and deactivation. It is easy to get wrong in a way that still runs and still looks plausible. Here is how it works, how to set it up, and the one option that decides whether your residual stresses are right.
What Abaqus model change actually does
The *MODEL CHANGE keyword removes elements from the active model or adds them back. A removed element contributes nothing: no stiffness, no mass, no conductivity, no output. In a contour plot a deactivated weld bead looks like a hole in the part.
Removal is not instantaneous. When Abaqus/Standard removes elements, the forces they were applying to the remaining nodes are ramped down to zero over the step. That stops a static analysis from seeing a sudden load drop it cannot handle — and it means a removal step needs its own step time, not a load on top of it.
Every element must already exist in the model. Model change does not create geometry or mesh during the analysis. You mesh the final shape — full weld bead, full embankment, full printed part — then switch pieces off at the start and bring them back in the order the real process builds them.
Where you can and cannot use it
- Abaqus/Standard only.
*MODEL CHANGEis not available in Abaqus/Explicit. If your model needs explicit dynamics, you need a different approach (see the quiet element method below). - General steps only. Static, visco, heat transfer, and coupled temperature-displacement steps work. Linear perturbation steps such as frequency extraction and buckling do not.
- Contact pairs are separate. Removing elements does not remove a contact pair; that needs its own
TYPE=CONTACT PAIRentry.
The Abaqus keyword reference for *MODEL CHANGE lists the full set of restrictions for your version.
Setting it up in Abaqus/CAE
Model change lives in the Interaction module, not under Mesh or Step.
- Create an element set for each group you want to control — one set per weld pass, one per excavation lift. Do this while you mesh. It is the part of the job that actually takes time.
- Interaction module → Interaction → Create, pick the step, choose Model change.
- Set Region type: Elements and select the set.
- Set Activation state in this step to Deactivated or Reactivated.
- When reactivating, decide whether the elements come back strain free. Read the next section first.
Each interaction stays in force in later steps until you change it, so there is no need to repeat it. Deactivate the whole weld in step 1, then reactivate one pass per step.
The input file version
** switch a group off
*MODEL CHANGE, REMOVE
WELD_PASS_3
**
** bring it back with no initial strain
*MODEL CHANGE, ADD=STRAIN FREE
WELD_PASS_3
**
** bring it back carrying current deformation
*MODEL CHANGE, ADD=WITH STRAIN
WELD_PASS_3
These go inside the step definition. For a 20-pass weld, generating the sequence with a short Python or text script beats clicking through CAE dozens of times, and it makes the pass order easy to change later. The same logic applies to editing Abaqus INP files generally.
Strain free or with strain? This is the one that matters
ADD=STRAIN FREE is the default. It means the element is stress and strain free in its current deformed position: whatever the surrounding structure did while the element was switched off becomes the new reference configuration.
That is exactly what you want for deposited material. Weld filler and printed material arrive molten. They cannot carry the strain history of a plate that moved before they existed. Reactivate filler WITH STRAIN and you are telling Abaqus the filler was stretched along with the plate from the beginning. The residual stress field comes out wrong, often badly, and in a direction that is hard to spot without a benchmark.
ADD=WITH STRAIN does have uses, mostly structural problems where a member is temporarily removed and restored while the rest of the structure stays loaded. For process simulation, strain free is almost always correct. Check your version’s documentation — the with-strain option is not valid in every situation.
Birth and death for welding and additive manufacturing
This is where most engineers meet model change. The process is sequential: metal arrives, heats the material around it, cools, shrinks, and leaves residual stress behind. A model with the whole bead present from increment one cannot reproduce that. The standard sequentially coupled workflow has two passes.
Thermal pass
Run a heat transfer analysis. Deactivate all weld passes in step 1, then reactivate one pass per step as the torch reaches it. Apply the moving heat source over the activated pass — usually a Goldak double-ellipsoid distribution through a DFLUX subroutine. Write the nodal temperature history to the ODB.
Watch the film and radiation conditions on surfaces that only exist after a pass is activated. A surface buried inside the finished weld should not be losing heat to air for the whole analysis.
Mechanical pass
Run a static step (or visco, if you want creep relaxation) on an identical mesh. Read the temperatures in as a predefined field from the thermal ODB and repeat exactly the same activation sequence, strain free this time.
The two sequences must match step by step. A mismatch is the most common silent error in weld modelling: the job completes, the plot looks like a weld, and the stresses are meaningless. Compare peak residual stress against a published case for the same material and thickness before you trust it.
For additive manufacturing with hundreds of layers, hand-written model change stops being practical. The Abaqus AM plug-in drives progressive element activation from an event series and toolpath data instead. The physics is identical — material appears strain free, then shrinks.
Staged construction and excavation
Civil and geotechnical models use the same feature in reverse. Mesh the full soil domain, then remove the excavated elements one lift per step. The ramped force removal is what makes this physically reasonable: the ground gives up its support gradually instead of vanishing in one increment.
The same pattern covers embankment construction in lifts, tunnel lining behind a cutting face, props removed after a slab cures, and bolts installed partway through a load history. Reactivated members usually want strain free too — a bolt installed today was not carrying yesterday’s load.
Model change or the quiet element method?
There is an alternative. Instead of removing elements, you give the not-yet-deposited material near-zero stiffness and conductivity, then switch it to real properties on deposition, typically through a field variable driven by a USDFLD subroutine.
- Model change is cleaner, needs no subroutine, and removes the degrees of freedom entirely, so it solves faster. Abaqus/Standard only.
- Quiet elements keep every degree of freedom active, which costs solver time and can introduce small spurious stresses in the dead material — but the method works where model change does not, and gives finer control over the transition.
For most welding and staged-construction work in Abaqus/Standard, model change is the simpler and more accurate starting point.
One thing it is not for: crack growth or material failure. Deleting elements by hand to represent cracking gives a mesh-dependent answer that depends on your element sets, not on the material. Use a damage model, cohesive elements, or XFEM crack growth for that.
Common mistakes
- Trying it in Abaqus/Explicit. Check your step type before anything else.
- Reactivating weld filler with strain. The most damaging error here. Wrong residual stress, and the model still runs.
- Numerical singularity warnings. A node belonging only to removed elements has no stiffness left, and Abaqus warns about zero pivots. Often harmless — but open the message file and confirm those nodes do not carry loads or boundary conditions you still need.
- Boundary conditions and loads left on removed regions. Removing elements does not remove them. Suppress them in the same step.
- Removal mixed with loading in one step. The ramped removal forces tangle with your load history. Give removal its own step.
- Thermal and mechanical sequences out of step. In a sequentially coupled weld model they must activate the same sets in the same order.
- Element sets built too late. Retrofitting pass-by-pass sets onto a finished mesh is painful and error-prone.
Ready-to-use models
Working from a model that already runs is the fastest way to learn this: you see the step structure, the element sets, and the activation order together in one file.
- Welding Simulation Package in Abaqus (14 Models with DFLUX) — complete weld models with moving heat sources and sequential activation, covering plates, pipes, and multi-pass joints.
- Abaqus model to predict residual stress in welding or additive manufacturing — a focused thermal-mechanical model showing the two-pass workflow end to end.
- Abaqus AM Plug-in Tutorial — progressive element activation for additive manufacturing, for when layer counts make manual model change impractical.
- Embankment and excavation on saturated soil in Abaqus — the geotechnical side of the same feature, with staged removal and construction.
FAQ
Does Abaqus model change work in Abaqus/Explicit?
No. *MODEL CHANGE is an Abaqus/Standard feature. In Abaqus/Explicit you need another route, such as element deletion driven by a damage model, or a material-state (quiet element) approach.
Should weld filler be reactivated strain free or with strain?
Strain free, which is the default. Deposited material arrives molten and cannot carry the deformation history of the parts around it. Reactivating with strain produces incorrect residual stress.
Why do I get numerical singularity warnings after removing elements?
Nodes that belonged only to the removed elements have no stiffness left. The warnings are often harmless, but check the message file and confirm none of those nodes carry loads or boundary conditions you still need.
Can I add elements that were not in the original model?
No. Model change only switches existing elements on and off. Mesh the final configuration first, then deactivate what has not been built yet.
Do I still need a DFLUX subroutine if I use model change?
Usually yes, for welding. Model change controls when material exists; DFLUX controls the moving heat source that melts it. A realistic weld model needs both. Note that Fortran is the official language for Abaqus user subroutines.
Where to go next
For a worked process case that leans on all of this at once, see our guide to WAAM simulation in Abaqus, where strain-free element activation and a moving heat source have to agree with measured distortion.
Model change takes an afternoon to learn and then improves every process model you build afterwards. Get the element sets right, use strain-free reactivation for deposited material, keep the thermal and mechanical sequences aligned, and read the message file.
If you want a working file to start from, browse the simulation models and tutorial packages in the shop. If you have a weld, additive manufacturing, or staged-construction problem on a deadline and would rather hand it over, our engineering simulation services cover model setup, validation, and reporting.