ANSYS Fatigue Tool: Setup, Results and Common Mistakes

ANSYS Fatigue Tool: Setup, Results and Common Mistakes

Table of Contents

You run a static structural analysis in ANSYS Workbench, add the Fatigue Tool, and the Life plot comes back as a flat 1e9 cycles everywhere — or as a few hundred cycles at one sharp corner. Neither number looks believable, and nothing in the result tree tells you which input caused it.

That is normal. The ANSYS Fatigue Tool is a post-processor with about six settings, and five of them change the answer by orders of magnitude. This guide walks through what each setting does, how to read Life, Damage and Safety Factor without fooling yourself, and the mistakes that produce the strange plots above.

What the ANSYS Fatigue Tool actually does

The Fatigue Tool does not solve anything new. It takes the stress (or strain) field that Mechanical already computed and runs a classical fatigue calculation on it, node by node:

  1. It builds a stress amplitude and a mean stress at each node from your single solved load case.
  2. It corrects the amplitude for mean stress.
  3. It looks the corrected amplitude up on the S-N curve stored in Engineering Data.
  4. It reports cycles to failure at that node.

So it is a crack initiation calculation on a linear-elastic stress field. It knows nothing about cracks, weld geometry, surface finish beyond a single factor, or load sequence — unless you tell it.

The three inputs that decide your answer

1. The S-N curve in Engineering Data

This is the number one reason fatigue results look wrong. Open Engineering Data → your material → Life (Fatigue) and check that an Alternating Stress Mean Stress table exists. Most materials in the sample library have none. Without it, the Fatigue Tool cannot produce a Life result.

Two things to know about the default Structural Steel curve:

  • It is the ASME Boiler and Pressure Vessel Code design curve (Section VIII, Division 2), not raw test data. It already contains a margin, so your Life will be conservative compared with a handbook S-N curve for the same steel.
  • Its last point sets where Life saturates. Combined with the Infinite Life setting (default 1e9 cycles), that is why so many Life plots are a uniform 1e9 — the stresses are simply below the endurance limit everywhere.

Check units too. If your model is in MPa and the S-N table was entered in Pa, every life number is meaningless.

2. Loading type

The Fatigue Tool turns one solved load case into a cycle. How it does that depends on Type:

TypeWhat it meansR ratio
Fully ReversedLoad swings ±solved value, mean = 0−1
Zero-BasedLoad goes 0 → solved value → 00
RatioYou give R directlyyour value
History DataA load-time file, rainflow countedmixed

Fully Reversed with mean stress theory set to None is the default, and it is the most optimistic combination available. A zero-based cycle at the same amplitude has a tensile mean stress and a shorter life.

The Scale Factor field is useful: solve one unit load, then scale it. You get a new fatigue answer in seconds without re-solving.

3. Stress component

Stress Component tells the tool how to collapse a 3D stress tensor into one scalar amplitude. Signed von Mises is the usual choice because it keeps the sign of the hydrostatic part, so compression is not treated as tension.

This step is also the biggest approximation in the whole method. Stress-life with a single S-N curve assumes the stress state at the critical point behaves like a uniaxial test specimen. Insert a Biaxiality Indication result and check:

  • 0 — uniaxial. The assumption holds.
  • −1 — pure shear.
  • 1 — equibiaxial.

If biaxiality at your critical node sits far from 0, or changes through the load cycle, a uniaxial stress-life answer is a rough estimate, not a number to put in a report.

Step-by-step setup in Workbench Mechanical

  1. Solve the static structural analysis first. Confirm the stress field is sensible before any fatigue work.
  2. Right-click Solution → Insert → Fatigue → Fatigue Tool.
  3. In the Fatigue Tool details:
    • Fatigue Strength Factor (Kf) — knocks the S-N curve down for surface finish, size and reliability. 1.0 means a polished lab specimen. For a machined part, 0.7–0.9 is a common starting range, but take the value from your own code or test data.
    • Type / Scale Factor — as above.
    • Analysis Type — Stress Life for high-cycle, Strain Life for low-cycle with local plasticity.
    • Mean Stress Theory — None, Goodman, Soderberg, Gerber, or Mean Stress Curves if your material has multi-R data.
    • Stress Component — Signed von Mises for most structural work.
    • Infinite Life — the ceiling on reported Life.
  4. Right-click the Fatigue Tool and insert the results you need: Life, Damage, Safety Factor, Biaxiality Indication, Equivalent Alternating Stress, Fatigue Sensitivity.
  5. For Damage and Safety Factor, set Design Life to the number of cycles the part must survive. This is a required input, and the default is not your design life.
  6. Evaluate. No re-solve is needed, so changing a setting and re-evaluating takes seconds.

If you prefer driving this from a script, the same settings are reachable through command objects — see our guide to APDL commands in ANSYS Workbench.

Reading Life, Damage and Safety Factor correctly

Life is cycles to crack initiation at each node, capped at the Infinite Life value.

Damage is the Palmgren-Miner ratio:

Damage = Design Life / Available Life

Damage above 1 means the part fails before the design life. Below 1 means it survives, with 0.1 meaning you have used 10% of the life.

Safety Factor is a factor on stress at the design life, not on life. A Safety Factor of 2 means the stress amplitude could double before the part fails at that design life. Because fatigue life goes roughly with stress to a power of 3 to 10, a stress safety factor of 1.2 can still represent a very large life margin. Do not read it as “twice the life”.

The Fatigue Sensitivity chart is the cheapest useful result in the tool. It sweeps your loading up and down by a percentage and plots life against it. If life collapses between 90% and 110% of the design load, your margin is not real.

Common mistakes

1. Reporting the peak Life at a sharp corner. A re-entrant corner with no fillet is a stress singularity. Refine the mesh and the stress grows without limit, so Life falls without limit. Model the real fillet radius, or use a mesh-insensitive method such as hot-spot stress extrapolation. Never resolve this by coarsening the mesh until the number looks acceptable.

2. Leaving Mean Stress Theory at None for a zero-based cycle. You are then ignoring a tensile mean stress equal to half the peak. Goodman is the conservative default for metals:

σar = σa / (1 − σm / σu)

3. Using plain-material S-N data for a welded joint. Weld fatigue is governed by the joint class, not the parent metal. Codes such as IIW, BS 7608 and Eurocode 3 use nominal, hot-spot or effective-notch stress with their own detail categories. Running the standard Fatigue Tool on a weld toe will usually be optimistic and is not defensible in a code assessment.

4. Running Stress Life on a model with significant plasticity. Stress-life assumes nominally elastic behaviour. If the critical location yields, switch to Strain Life, which applies a Neuber correction, and give the material its strain-life constants. If you are modelling cyclic plasticity properly, you also need a hardening model that captures it — see the ANSYS Chaboche nonlinear kinematic hardening guide.

5. Expecting crack growth. The Fatigue Tool gives life to initiation. If a crack already exists, or you need remaining life of a flawed component, you need fracture mechanics: stress intensity factor, Paris law, and a standard such as API 579. That is a different calculation entirely.

6. Forgetting that one solved load case is one cycle. Real duty cycles have several load blocks. Use History Data with a load-time file so the tool can rainflow count it (ASTM E1049 is the reference practice), then read the Rainflow and Damage matrices. With a single load case you are assuming constant amplitude.

Vibration-driven fatigue is a case in point: the stress amplitudes have to come from a frequency-domain run first, such as a harmonic response analysis in ANSYS Workbench.

When to leave the Fatigue Tool

The built-in tool is good for a quick high-cycle screen on a mostly uniaxial part. Move to dedicated fatigue software — fe-safe or nCode DesignLife — when you need critical-plane multiaxial methods, weld methods, FKM or BS 7608 assessments, or damage from long measured load histories. Ansys publishes its own overview of the method in Topics in Fatigue Analysis in Ansys Mechanical.

And when a crack is already present, move to fracture mechanics instead of life curves.

Ready-to-use models

If you would rather start from a working model than build one from nothing, these packages on Engineering Downloads cover the next steps after the Fatigue Tool:

FAQ

Why is my ANSYS fatigue life 1e9 everywhere?

Your equivalent alternating stress is below the last point on the S-N curve, so every node is reported at the Infinite Life value. Check the stress magnitudes first, then check that the S-N table units match the model, then check the Fatigue Strength Factor. A uniform plot is usually a real result, not a bug.

Does the Fatigue Tool work with a nonlinear analysis?

It will produce numbers from a nonlinear solution, but Stress Life assumes nominally elastic behaviour, so those numbers are unreliable once the critical location yields. Use Strain Life with proper strain-life material constants for low-cycle cases.

Which mean stress theory should I use?

If the material has multi-R S-N data, use Mean Stress Curves — it interpolates real data instead of assuming a correction. Otherwise Goodman is the common conservative choice for metals. Soderberg is more conservative, Gerber less so and generally used for ductile materials in compression-dominated cases.

Can the ANSYS Fatigue Tool predict crack growth?

No. It predicts cycles to crack initiation from an uncracked stress field. Crack growth needs a fracture-mechanics calculation — stress intensity factor range, Paris law, and a flaw geometry — which in ANSYS means SMART crack growth or a dedicated assessment to API 579.

What is a good Fatigue Strength Factor?

It depends on the surface, the size and the reliability you need, so there is no universal value. 1.0 represents a polished specimen. Machined surfaces, forgings and corrosive service all reduce it. Take the factor from the code you are working to, or from test data on your own material and finish, rather than from a default.

Conclusion

The ANSYS Fatigue Tool is fast and useful as long as you treat it as what it is: a uniaxial stress-life screen on an elastic stress field. Get the S-N data right, set the loading type and mean stress theory deliberately, check biaxiality at the critical node, and never report a life taken from a singularity.

Browse the full library of ready-to-use ANSYS and Abaqus models, tutorials and courses in the Engineering Downloads shop. If you need a fatigue or fracture assessment done and signed off rather than learned, our engineering services and custom simulation page is the place to start.

Leave a Reply

Your email address will not be published. Required fields are marked *

Related  articles

Abaqus Integration Point vs Nodal Stress: Why Peaks Differ
Compare integration-point, element-nodal and unique-nodal stress in Abaqus, and check whether a contour peak depends on extrapolation, averaging or mesh size.
Abaqus Linear Perturbation vs General Step: What Actually Changes
Abaqus Linear Perturbation vs General Step: What Actually Changes

You run a frequency extraction after a static step and the frequencies come out the same whether or not the part had yielded. You run a static linear perturbation step and the reaction force is a fraction of what you

Harmonic Response Analysis in ANSYS Workbench: A Practical Guide
Harmonic Response Analysis in ANSYS Workbench: A Practical Guide
How to set up harmonic response analysis in ANSYS Workbench: modal link, frequency range, solution method, damping, loads and results, plus the common mistakes.

See more

Related  Products

See more